AC/DC Current Sensor (DC-2MHz, 500A, 10m Cable) CT6875-01

(0) No Reviews yet
$1,914.00
SKU: CT6875-01
Ships in approximately 20 days if not in stock.

Contact for Lead Time

Hioki pass-through AC/DC current sensors are best-in-class devices for use with power analyzers, Memory HiCorders and high performance oscilloscopes. The CT6875 is a DC to 2MHz/500A sensor, ideal for testing inverter efficiency, inverter output power, reactor or transformer loss.

The sensor uses flux gate detection within the zero flux method to deliver outstanding linear properties, enabling it to maintain high precision even at low current levels.

CAT III 1000 V

Key Features
- Strengthened shield improves noise resistance to accurately measure?current buried in noise
- Flat frequency characteristics and CMRR performance to achieve high accuracy?measurement
- More enhanced environmental resistance performance than ever before with operating temperature range of -40 to?85 degrees C


Included Accesories:
Instruction manual ×1, Mark bands ×6, Operating precautions ×1
Rated current500 A AC/DC
Max. allowable inputWithin the derating range, up to ±1500 Apeak (design value) allowed at 40°C or less for 20 ms or less
Frequency bandwidthAmplitude: DC to 2 MHz (CT6875), DC to 1.5 MHz (CT6875-01)
Phase: DC to 1 MHz
Basic accuracy(DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.1°
Output voltage rate4 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit. Use with voltage input equipment with high input impedance such as 1 MΩ)
Max. rated voltage to earth1000 V AC/DC (50/60 Hz, CAT III )
Core diameterφ 36 mm (1.42 in)
Operating temperature, humidity-40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation)
Power supplyPower suppled via the Power Analyzer PW6001, PW3390, or Sensor Unit CT9555, CT9556, CT9557
Max. rated power7 VA max. (at 500 A/55 Hz)
Dimensions and mass160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, CT6875: 800 g (28.2 oz), cable length 3 m (9.84 ft), CT6875-01: 1100 g (38.8 oz), cable length 10 m (32.81 ft)
Included AccessoriesInstruction manual ×1, Mark bands ×6, Operating precautions ×1

Compatible models

Compatible modelsCT6875
Power Analyzer PW6001, PW3390Ok
Power Analyzer 3390Attention (Requires CT9901)
Power HiTester 3193 seriesAttention (Requires CT9901)
Current Unit 8971Attention (Requires the 9318, CT9901)

ACCESSORIES



CONNECTION CORD 9165
- Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length



CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length



SENSOR UNIT CT9555
- 1 channel
- Waveform output



SENSOR UNIT CT9556
- 1 channel, ±0.2% DC accuracy
- Waveform and RMS output



SENSOR UNIT CT9557
- 4 channels, ±0.06% DC accuracy
- Waveform, total waveform, and total RMS output



EXTENSION CABLE CT9902 
- 5 m (16.41 ft) length, ME15W (12 pin) - ME15W (12 pin) connector



CONVERSION CABLE CT9901
- ME15W (12 pin) to PL23 (10 pin) connector

OPTIONS


CT6875
- 500 A AC/DC, ME15W terminal, 3 m (9.84 ft) cable length

Ratings & Reviews

No reviews available

Be the first to Write a Review