AC/DC Current Sensor (DC-1.5MHz, 1000A, 10m Cable) CT6876-01

(0) No Reviews yet
$2,145.00
SKU: CT6876-01
Ships in approximately 20 days if not in stock.

Contact for Lead Time

1000 A AC/DC, ME15W terminal, 10 m (32.81 ft) cable length
Hioki pass-through AC/DC current sensors are best-in-class devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT6876 is a DC to 1.5MHz/1000A sensor, ideal for testing inverter efficiency, inverter output power, reactor or transformer loss.

The sensor uses flux gate detection within the zero flux method to deliver outstanding linear properties, enabling it to maintain high precision even at low current levels.


CAT III 1000 V

Key Features
- The ideal current sensor for measuring large 1000 A currents in EV, HEV, and PHEV
- Strengthened shield improves noise resistance to accurately measure current buried in noise
- Flat frequency characteristics and CMRR performance to achieve high accuracy measurement
- More enhanced environmental resistance performance than ever before with operating temperature range of -40 to 85degreeC
- Basic accuracy of 0.04% and phase 0.1degree
- Good frequency characteristics over wide band of DC to 1.5 MHz (amplitude) and DC to 1 MHz (phase)
- Ideal for advanced fields such as photovoltaics and fuel cells to evaluate the charge / discharge of batteries and secondary side of inverters
- Connect with oscilloscopes or Hioki Memory HiCorders (using SENSOR UNIT) to monitor

Included Accessories:
Instruction manual ×1, Mark bands ×6, Operating precautions ×1
Rated current1000 A AC/DC
Max. allowable inputWithin the derating range, up to ±1800 Apeak (design value) allowed at 40°C or less for 20 ms or less
Frequency bandwidthAmplitude: DC to 1.5 MHz (CT6876), DC to 1.2 MHz (CT6876-01)
Phase: DC to 1 MHz
Basic accuracy(DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.1°
Output voltage rate2 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit. Use with voltage input equipment with high input impedance such as 1 MΩ)
Max. rated voltage to earth1000 V AC/DC (50/60 Hz, CAT III )
Core diameterφ 36 mm (1.42 in)
Operating temperature, humidity-40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation)
Power supplyPower suppled via the Power Analyzer PW6001, PW3390, or Sensor Unit CT9555, CT9556, CT9557
Max. rated power7.5 VA max. (at 1000 A/55 Hz)
Dimensions and mass160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, CT6876: 950 g (33.5 oz), cable length 3 m (9.84 ft), CT6876-01: 1250 g (44.1 oz), cable length 10 m (32.81 ft)
Included AccessoriesInstruction manual ×1, Mark bands ×6, Operating precautions ×1

Compatible models

Compatible modelsCT6876
Power Analyzer PW6001, PW3390Ok
Power Analyzer 3390Attention (Requires CT9901)
CT ratio 2
Power HiTester 3193 seriesAttention (Requires CT9901)
CT ratio 2
Current Unit 8971Attention (Requires the 9318, CT9901) CT ratio 2

Ratings & Reviews

No reviews available

Be the first to Write a Review