AC/DC Current Sensor (DC-1MHz, 2000A, 3m Cable) CT6877
Hioki pass-through AC/DC current sensors are best-in-class devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT6877 is a DC to 1 MHz/2000A sensor, ideal for evaluating the inverter power conversion efficiency in next generation devices.
The CT6877 delivers a wide frequency band and excellent noise resistance, prerequisites for properly evaluating inverters motors used in electric vehicles and hybrid vehicles, a class of devices that continue to move toward ever larger currents and higher-frequency switching.
CAT III 1000 V
Key Features
- Easily measure large 2000A currents to meet applications in EV, HEV testing
- Improved noise resistance performance through a stronger shield lets you accurately measure current buried in noise
- High accuracy measurement realized through flat frequency characteristics and CMRR performance
- More enhanced environmental resistance performance than ever before lets you measure in -40 to 85degreeC situations
- Improved basic accuracy of 0.04% and phase accuracy of 0.1degree
- Superior frequency characteristics of DC to 1 MHz (amplitude)
- Meet a wide range of applications from measuring battery charge/discharge to the secondary side of inverters in photovoltaic power generation and fuel cell evaluation, etc.
- Monitor waveforms when paired with oscilloscopes or Memory HiCorders and Sensor Unit
Product Warranty Period: 3
Included Accessories:
Instruction manual ×1, Mark bands ×6, Operating precautions ×1
Rated current | 2000 A AC/DC |
---|---|
Max. allowable input | Within the derating range, (within the specified range up to ±3200 Apeak ) |
Frequency characteristics | Amplitude: DC to 1 MHz, Phase: DC to 700 kHz |
Basic accuracy | (DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.1° |
Output voltage rate | 1 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit. Use with voltage input equipment with high input impedance such as 1 MΩ) |
Max. rated voltage to earth | 1000 V AC/DC (50/60 Hz, CAT III ) |
Core diameter | φ 80 mm (3.15 in) |
Operating temperature, humidity | -40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation) |
Power supply | Power suppled via the Power Analyzer PW6001, PW3390, or Sensor Unit CT9555, CT9556, CT9557 |
Max. rated power | 9.5 VA max. (at 2000 A/55 Hz, ±12 V power requirement) |
Dimensions and mass | 229 mm (9.02 in)W × 232 mm (9.13 in)H × 112 mm (4.41 in)D, CT6877: 5 kg (176.4 oz), cable length 3 m (9.84 ft), CT6877-01: 5.3 kg (186.9 oz), cable length 10 m (32.81 ft) |
Included Accessories | Instruction manual ×1, Mark bands ×6, Operating precautions ×1 |
ACCESSORIES
CONNECTION CORD 9165
- Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
SENSOR UNIT CT9555
- 1 channel
- Waveform output
SENSOR UNIT CT9556
- 1 channel, ±0.2% DC accuracy
- Waveform and RMS output
SENSOR UNIT CT9557
- 4 channels, ±0.06% DC accuracy
- Waveform, total waveform, and total RMS output
EXTENSION CABLE CT9902
- 5 m (16.41 ft) length, ME15W (12 pin) - ME15W (12 pin) connector
CONVERSION CABLE CT9901
- ME15W (12 pin) to PL23 (10 pin) connector
DOWNLOADS
Catalog
- AC/DC CURRENT SENSOR CT6877, CT6876, CT6875
Declaration of Conformity
- AC/DC CURRENT SENSOR CT6875,CT6876