Digital Multimeter with Wireless Adapter DT4261-90

1Review
$347.00
SKU: DT4261-90

This item is IN STOCK

The Hioki DT4261 Digital Multimeter offers all the necessary features required by professional technicians around the world with a super-fast response rate and safety features that take electrical testing to the next level.

Key Features
- Measure a wide variety of parameters such as AC/DC voltage, AC/DC current, frequency, capacitance, diode, resistance and continuity.
- Includes other specifications for safe measurements in the toughest environments, CAT IV 600V / CAT III 1000V, drop proof (1m), Low Z V, terminal shutter protection, -25C to 65C operating temperature, fuse check and IP54.
- Compatible with Bluetooth adapter Z3210 which allows connection with Gennect Cross. With Gennect Cross you can see waveforms, harmonics, data logging and other unique features in a DMM.


Included Accessories:
Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1

Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.

DC Voltage range600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt.
AC Voltage range6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 Hz - 500 Hz: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less)
DC + AC Voltage range6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz
Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
LoZ V600.0 V, 1 range, Frequency characteristics: DC, 40 Hz to 1 kHz
Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
Resistance range600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±3 dgt.
DC Current range600.0 mA to 10.00 A, 3 ranges
Basic accuracy: ±0.5% rdg. ±3 dgt.
AC Current range600.0 mA to 10.00 A, 3 ranges
Basic accuracy 40 Hz - 500 Hz: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less)
Frequency characteristics: 40 Hz to 1 kHz
AC Current range (use with Clamp on probes)10.00 A to 1000 A, 7 ranges
Basic accuracy 40 Hz - 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less)
Capacitance range1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt.
Continuity CheckContinuity threshold ON : 25 Ω, Continuity threshold OFF : 245 Ω, Response time: 0.5 ms or more
Diode testOpen terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V
Voltage frequency range99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Current frequency range99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current)
Basic accuracy: ±0.1% rdg. ±1 dgt.
Other functionsMis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed)
DisplayMain and sub displays: 4-digits LCD, max. 6000 digits (excluding frequency measurement), bar-graph
Display refresh rates5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 times/s)
Power supplyLR6 (AA) alkaline batteries × 3, Continuous operating time: 130 hr. (without Z3210 installed), 70 hr. (with Z3210 installed and using wireless communications)
Dimensions and mass87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D, 480 g (16.9 oz.) (with test leads holder and batteries)
Included AccessoriesTest Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1

Accessories

500 A to 5000 A
*For commercial power lines, 50/60 Hz





CLAMP ON PROBE 9132-50
- Use for level measurement 
- 40 Hz to 1 kHz 
- 20 to 1000A AC 
- 0.2 V AC/range output 
- φ 55 mm (2.17 in) core dia.




CLAMP ON PROBE 9018-50
- Excellent phase characteristics 
- 40 Hz to 3 kHz 
- 10 to 500A AC 
- 0.2V AC/range output 
- φ 46 mm (1.81 in) core dia.


Input cable (F)
* Voltage input via banana terminals limited by the voltage specifications of the respective input unit.



MAGNETIC ADAPTER SET L4937
- Attaches to the tip of the banana plug cable, CAT III 1000V



BUS BAR CLIP SET L4936
- Attaches to the tip of the banana plug cable, CAT III 600V



ALLIGATOR CLIP SET L4935
- Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V



EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length



Input cable options
Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.




BREAKER PIN SET L4939
- Attaches to the tip of the banana plug cable, CAT III 600V




TEST PIN SET L4938
- Attaches to the tip of the banana plug cable, CAT III 600V




SMALL ALLIGATOR CLIP SET L4934
- Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V




TEST PIN SET L4932
- Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V


Input cables
 



GRABBER CLIP L9243 (185mm)
- Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length


Input Probes
*L9170-10 is a bundled accessory. 
*Requires the 9704 to connect a Clamp-on probe

 


CLAMP ON PROBE 9010-50
- Use for level measurement 
- 40 Hz to 1 kHz 
- 10 to 500 A AC 
- 0.2 V AC/range output 
- φ 46 mm (1.81 in) core dia.




CONVERSION ADAPTER 9704
- Receiving end: Female BNC; Output end: Male banana-plug 
*Not compatible with older generation Memory Hicorders with banana input terminals


Options for Test leads
Options for the L4930




MAGNETIC ADAPTER 9804
- Attaches to the tip of voltage cord, φ11 mm (0.43 in), compatible M6 pan screws


Other options
*C0203 is bundled.




COMMUNICATION PACKAGE (USB) DT4900-01
- For DT4280s/4250s, compatible to Windows 8.1/ 8/ 7/ Vista




CARRYING CASE C0202


Strap options
When using with the PQ 3100, suspend the main body on the metal surface using two Z5020 powerful type. Z5004 hang the cords on the metal surface.

 


MAGNETIC STRAP Z5020
- Extra strength




MAGNETIC STRAP Z5004


Test leads A
Options for the L9207-10

 


TEST LEAD L9207-10
- 90 cm (2.95 ft) length




CONTACT PIN SET L4933
- Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 70V DC/ 33V AC


Test leads B
Options for the L4930, Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.

 


CONNECTION CABLE SET L4930
- 1.2 m (3.94 ft) length



Voltage Input
*The L1000 is bundled with PQ3198 *Please inquire about voltage cord extension




EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length

DOWNLOADS

Catalog
DIGITAL MULTIMETER DT4261

Manual
DIGITAL MULTIMETER DT4261

Declaration of Conformity
DIGITAL MULTIMETER DT4261

Ratings & Reviews

1 review

  • 4 stars
  • 0 reviews
  • 3 stars
  • 0 reviews
  • 2 stars
  • 0 reviews
  • 1 star
  • 0 reviews
6/17/2023 5:08 am

Great meter, Bluetooth connection makes it even better

Ryan H.

This is a very high quality and fast meter. It is fast and accurate, feels very durable, and the Bluetooth functions very well with my android phone. I've been using it for about a year and a half in a factory environment.

The meter shipped quickly and arrived nicely packaged in perfect condition.

Write a Review