Digital Multimeter with Wireless Adapter DT4261-90
The Hioki DT4261 Digital Multimeter offers all the necessary features required by professional technicians around the world with a super-fast response rate and safety features that take electrical testing to the next level.
Key Features
- Measure a wide variety of parameters such as AC/DC voltage, AC/DC current, frequency, capacitance, diode, resistance and continuity.
- Includes other specifications for safe measurements in the toughest environments, CAT IV 600V / CAT III 1000V, drop proof (1m), Low Z V, terminal shutter protection, -25C to 65C operating temperature, fuse check and IP54.
- Compatible with Bluetooth adapter Z3210 which allows connection with Gennect Cross. With Gennect Cross you can see waveforms, harmonics, data logging and other unique features in a DMM.
Included Accessories:
Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1
Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
DC Voltage range | 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.15% rdg. ±2 dgt. |
---|---|
AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 Hz - 500 Hz: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
DC + AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: DC, 40 Hz to 1 kHz Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
LoZ V | 600.0 V, 1 range, Frequency characteristics: DC, 40 Hz to 1 kHz Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less) |
Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±3 dgt. |
DC Current range | 600.0 mA to 10.00 A, 3 ranges Basic accuracy: ±0.5% rdg. ±3 dgt. |
AC Current range | 600.0 mA to 10.00 A, 3 ranges Basic accuracy 40 Hz - 500 Hz: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less) Frequency characteristics: 40 Hz to 1 kHz |
AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges Basic accuracy 40 Hz - 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less) |
Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
Continuity Check | Continuity threshold ON : 25 Ω, Continuity threshold OFF : 245 Ω, Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less, Threshold of forward voltage: 0.15 V to 1.8 V |
Voltage frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (Limited by minimum sensitivity voltage) Basic accuracy: ±0.1% rdg. ±1 dgt. |
Current frequency range | 99.99 Hz to 9.999 kHz, 3 ranges (Limited by minimum sensitivity current) Basic accuracy: ±0.1% rdg. ±1 dgt. |
Other functions | Mis-insertion prevention shutters, fuse check function, user setting retention function, filter function, zero-adjustment, display value hold, auto hold, MAX/MIN value display, PEAK value display, auto-power save, USB communication (when optional Communication Package DT4900-01 is installed), wireless communication (when optional Wireless Adapter Z3210 is installed) |
Display | Main and sub displays: 4-digits LCD, max. 6000 digits (excluding frequency measurement), bar-graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 times/s) |
Power supply | LR6 (AA) alkaline batteries × 3, Continuous operating time: 130 hr. (without Z3210 installed), 70 hr. (with Z3210 installed and using wireless communications) |
Dimensions and mass | 87 mm (3.43 in.) W × 185 mm (7.28 in.) H × 47 mm (1.85 in.) D, 480 g (16.9 oz.) (with test leads holder and batteries) |
Included Accessories | Test Lead L9300 × 1, Instruction Manual × 1, LR6 (AA) alkaline battery × 3, Operating Precautions ×1 |
Accessories
500 A to 5000 A
*For commercial power lines, 50/60 Hz
CLAMP ON PROBE 9132-50
- Use for level measurement
- 40 Hz to 1 kHz
- 20 to 1000A AC
- 0.2 V AC/range output
- φ 55 mm (2.17 in) core dia.
CLAMP ON PROBE 9018-50
- Excellent phase characteristics
- 40 Hz to 3 kHz
- 10 to 500A AC
- 0.2V AC/range output
- φ 46 mm (1.81 in) core dia.
Input cable (F)
* Voltage input via banana terminals limited by the voltage specifications of the respective input unit.
MAGNETIC ADAPTER SET L4937
- Attaches to the tip of the banana plug cable, CAT III 1000V
BUS BAR CLIP SET L4936
- Attaches to the tip of the banana plug cable, CAT III 600V
ALLIGATOR CLIP SET L4935
- Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
Input cable options
Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.
BREAKER PIN SET L4939
- Attaches to the tip of the banana plug cable, CAT III 600V
TEST PIN SET L4938
- Attaches to the tip of the banana plug cable, CAT III 600V
SMALL ALLIGATOR CLIP SET L4934
- Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V
TEST PIN SET L4932
- Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
Input cables
GRABBER CLIP L9243 (185mm)
- Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length
Input Probes
*L9170-10 is a bundled accessory.
*Requires the 9704 to connect a Clamp-on probe
CLAMP ON PROBE 9010-50
- Use for level measurement
- 40 Hz to 1 kHz
- 10 to 500 A AC
- 0.2 V AC/range output
- φ 46 mm (1.81 in) core dia.
CONVERSION ADAPTER 9704
- Receiving end: Female BNC; Output end: Male banana-plug
*Not compatible with older generation Memory Hicorders with banana input terminals
Options for Test leads
Options for the L4930
MAGNETIC ADAPTER 9804
- Attaches to the tip of voltage cord, φ11 mm (0.43 in), compatible M6 pan screws
Other options
*C0203 is bundled.
COMMUNICATION PACKAGE (USB) DT4900-01
- For DT4280s/4250s, compatible to Windows 8.1/ 8/ 7/ Vista
CARRYING CASE C0202
Strap options
When using with the PQ 3100, suspend the main body on the metal surface using two Z5020 powerful type. Z5004 hang the cords on the metal surface.
MAGNETIC STRAP Z5020
- Extra strength
MAGNETIC STRAP Z5004
Test leads A
Options for the L9207-10
TEST LEAD L9207-10
- 90 cm (2.95 ft) length
CONTACT PIN SET L4933
- Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 70V DC/ 33V AC
Test leads B
Options for the L4930, Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.
CONNECTION CABLE SET L4930
- 1.2 m (3.94 ft) length
Voltage Input
*The L1000 is bundled with PQ3198 *Please inquire about voltage cord extension
EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
DOWNLOADS
Catalog
- DIGITAL MULTIMETER DT4261
Manual
- DIGITAL MULTIMETER DT4261
Declaration of Conformity
- DIGITAL MULTIMETER DT4261
Ratings & Reviews
1 review
Great meter, Bluetooth connection makes it even better
Ryan H.
This is a very high quality and fast meter. It is fast and accurate, feels very durable, and the Bluetooth functions very well with my android phone. I've been using it for about a year and a half in a factory environment.
The meter shipped quickly and arrived nicely packaged in perfect condition.