LCR METER IM3536-01 (10MHz)

(0) No Reviews yet
$9,000.00
SKU: IM3536-01

Indent Basis Only

Production delay is expected due to the worldwide component shortages. Please contact a Hioki representative for details.

Hioki LCR Meters and Impedance Analyzers range from 1mHz to 3GHz devices to suit a wide range of applications in the testing of electronic components. The IM3536 raises the industry standard for general-purpose LCR meters by offering a wide DC and 4Hz to 8MHz testing frequency while delivering 0.05% accuracy, ideal for evaluating the characteristics of next generation electronic components, including power supply inductors thanks to the instrument's maximum measurement frequency of 8MHz.

Key Features
- DC, 4Hz to 8MHz measurement frequency
- High-speed measurement of 1ms (fastest time)
- High-precision measurement of 0.05% rdg. (representative value)
- Guaranteed accuracy range from 1 mΩ, low-impedance measurement with unmatched repeatability
- DC bias function: Measure under conditions simulating actual use or in accordance with industry standards
- Exceptional specifications and cost-performance for a wide range of applications, from R&D to production lines

Included Accessories:
Power cord ×1, Instruction manual ×1, LCR application disc (Communications user manual) ×1
Measurement modesLCR (Measurement with single condition), Continuous testing (Continuous measurement under saved conditions)
Measurement parametersZ, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ), σ, ε
Measurement range100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
Display rangeZ: 0.00 m to 9.99999 GΩ, Y: 0.000 n to 9.99999 GS, θ: ± (0.000° to 180.000°), Q: ± (0.00 to 9999.99), Rdc: ± (0.00 m to 9.99999 GΩ),
D: ± (0.00000 to 9.99999), Δ%: ± (0.000 % to 999.999 %), or other
Basic accuracyZ ±0.05% rdg. θ: ±0.03° (representative value, Measurable range: 1 mΩ to 200 MΩ)
Measurement frequency4 Hz to 8 MHz (5 digits setting resolution, minimum resolution 10 mHz)
Measurement signal level[Normal mode: V mode/CV mode]
4 Hz to 1.0000 MHz: 10 mV to 5 Vrms (maximum 50 mArms)
1.0001 MHz to 8 MHz: 10 mV to 1 Vrms (maximum 10mArms)
[Low impedance high accuracy mode: V mode/CV mode]
4 Hz to 1.0000 MHz: 10 mV to 1 Vrms (maximum 100 mArms)
[Normal mode: CC mode]
4 Hz to 1.0000 MHz: 10 μA to 50 mArms (maximum 5 Vrms)
1.0001 MHz to 8 MHz: 10 μA to 10 mArms (maximum 1 Vrms)
[Low impedance high accuracy mode: CC mode]
4 Hz to 1.0000 MHz: 10 μA to 100 mArms (maximum 1 Vrms)
[DC resistance measurement]
Measurement signal level: Fixed at 1 V
DC bias measurementGenerating range: DC voltage 0 V to 2.50 V (10 mV resolution)
In low Z high accuracy mode: 0 V to 1 V (10 mV resolution)
Output impedanceNormal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω
Display5.7-inch color TFT with touch panel
FunctionsComparator, BIN measurement (10 categories for 2 measurement parameters), Trigger function, Open/short compensation, Contact check, Panel loading/saving, Memory function
InterfacesEXT. I/O( HANDLER) ,USB, USB flash drive, LAN, GP-IB, RS-232C, BCD
Power supply100 to 240 V AC, 50/60 Hz, 50 VA max.
Dimensions and mass330 mm (12.99 in) W × 119 mm (4.69 in) H × 230 mm (9.06 in) D, 4.2 kg (148.1 oz)
AccessoriesPower cord ×1, Instruction manual ×1, LCR application disc (Communications user manual) ×1
ACCESSORIES



SMD TEST FIXTURE IM9100
- Direct-connection testing
- Test SMDs with electrodes on the bottom
- DC to 8MHz
- Measurable sample sizes: 01005 to 0402 (EIA)



4-TERMINAL PROBE 9140-10
- Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)



TEST FIXTURE 9261-10
- Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)



TEST FIXTURE 9262
- Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)



SMD TEST FIXTURE 9263
- Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)



DC BIAS VOLTAGE UNIT 9268-10
- Direct connection type, 40 Hz to 8 MHz, maximum applied voltage of DC ±40 V



DC BIAS CURRENT UNIT 9269-10
- Direct connection type, 40 Hz to 2 MHz, maximum applied current of DC 2 A



4-TERMINAL PROBE 9500-10
- Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, measurable conductor diameter: φ0.3 mm (0.01 in) to 2 mm (0.08 in)



SMD TEST FIXTURE 9677
- Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)



SMD TEST FIXTURE 9699
- Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high



CONTACT TIPS IM9901
- To replace the tip on the L2001, regular size, bundled with the L2001



CONTACT TIPS IM9902
- To replace the tip on the L2001, small size



4-TERMINAL PROBE L2000
- Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)



PINCHER PROBE L2001
- DC to 8MHz, 50Ω termination
- Tip electrode spacing: 0.3 to 6 mm
- Measurable sample size: 0603 (EIA)



SMD TEST FIXTURE IM9110
- For direct connection two-wire testing
- DC to 1 MHz
- Measurable sample size: 008004 (EIA)



GP-IB CONNECTOR CABLE 9151-02
- 2 m (6.56 ft) length
- RS-232C CABLE 9637
- 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length
DOWNLOADS

Catalog
-LCR METER IM3536

Declaration of Conformity
-LCR METER IM3536,IM3536-01

OPTIONS


IM3536

Ratings & Reviews

No reviews available

Be the first to Write a Review