Memory HiCorder (54 CH) MR8740
The MR8740 and MR8741 are rack-mountable data acquisition systems that deliver high-speed, multi-channel measurements over maximum of 32+22 channels. The MR8990 DVM unit is a 2-channel input unit for the MR8740/MR8741 for measuring minute fluctuations in output from sensors in automobiles and other equipment and voltage fluctuations in devices such as batteries at high levels of precision and resolution.
Key Features
- Introducing the DVM Unit MR8990 with high 24-bit resolution! Perform high-speed, high-accuracy measurement without going through a scanner.
- Support for multi-channel measurement (MR8740: up to 54 ch; MR8741: up to 16 ch)
- Isolated input (between input channels; input-to-chassis isolation: maximum input-to-ground rated voltage of 300 V AC/DC)
- High-speed sampling (max. 20 MS/s; with 54-ch type, simultaneous sampling of up to 32 ch)
- Ideal for rack-mounting (4U height/within 180 mm; display-less, box-type design)
- Display waveforms and make settings on a DVI-D connected monitor and mouse
- Remote measurement via LAN using control commands from a PC
*Screen monitoring and remote operation available via Internet browser. For faster and more convenient remote operation, we recommend using the Hioki 9333 LAN Communicator.
Product Warranty Period: 3 years
Included Accessories:
Instruction manual × 1, Application disk (Wave viewer Wv, Communication commands table) × 1, Power cord × 1
Key Features
- Introducing the DVM Unit MR8990 with high 24-bit resolution! Perform high-speed, high-accuracy measurement without going through a scanner.
- Support for multi-channel measurement (MR8740: up to 54 ch; MR8741: up to 16 ch)
- Isolated input (between input channels; input-to-chassis isolation: maximum input-to-ground rated voltage of 300 V AC/DC)
- High-speed sampling (max. 20 MS/s; with 54-ch type, simultaneous sampling of up to 32 ch)
- Ideal for rack-mounting (4U height/within 180 mm; display-less, box-type design)
- Display waveforms and make settings on a DVI-D connected monitor and mouse
- Remote measurement via LAN using control commands from a PC
*Screen monitoring and remote operation available via Internet browser. For faster and more convenient remote operation, we recommend using the Hioki 9333 LAN Communicator.
Product Warranty Period: 3 years
Included Accessories:
Instruction manual × 1, Application disk (Wave viewer Wv, Communication commands table) × 1, Power cord × 1
Max. Number of channels | [Block I] 32 ch analog + 8 ch logic, or 29 ch analog + 56 ch logic (when used with built-in logic input + plug-in logic unit 8973 × 3) [Block II] 22 ch analog + 8 ch logic, or 19 ch analog + 56 ch logic (when used with built-in logic input + plug-in logic unit 8973 × 3) |
---|---|
Number of slots | [Block I] 16 slots (Max. 16) [Block II] 11 slots (Max. 11) [Limitation on number of slots] when using the Current Unit 8971: Max. 4, When using the Logic Unit 8973: [Block I] Max. 3; cannot use slots 9 to 16 [Block II] Max. 3; cannot use slots 9 to 11 |
Number of logic channels | [Block I] 8 ch logic (Logic probe terminal GND share a common GND with chassis. ) [Block II] 8 ch logic (Logic probe terminal GND share a common GND with chassis. ) [Limitation on using built-in logic input] applies to both Block I and Block II (with logic measurement ON) • Measurement resolution on slots 1 and 2 is limited up to 12 bits • Cannot use Frequency Unit 8970 on slots 1 and 2 • When using the DVM Unit MR8990 on slots 1 or 2: cannot use built-in logic input |
Measurement ranges (20 div full scale) | 5 mV to 20 V/div, 12 ranges, resolution : 1/100 of range (when using 8966) 5 mV to 50 V/div, 5 ranges, resolution : 1/50,000 of range (when using MR8990) |
Max. allowable input | 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage) |
Max. rated voltage to earth | 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage) |
Frequency characteristics | DC to 5 MHz (-3 dB, when using 8966) |
Time axis (MEMORY operation) | 5 µs to 5 min/div; 26 ranges; time axis resolution: 100 points/div; time axis expansion: 3 stages from ×2 to ×10; compression: 13 stages from 1/2 to 1/20,000 |
Measurement functions | Memory (high-speed recording), FFT |
Memory capacity | 16 MW/ch (fixed), total of 864 MW installed |
Removable storage | USB memory stick (USB 2.0) |
Display | None (1 digital DVI terminal per block, 800 × 600 dots) |
External interfaces | [LAN] 100Base-TX (DHCP and DNS support, FTP server, HTTP server) [USB] USB 2.0 Series A receptacle × 2 (mouse operation) |
Power supply | 100 to 240 V AC, 50/60 Hz (250 VA max.) |
Dimensions and mass | 426 mm (16.77 in) W × 177 mm (6.97 in) H × 505 mm (19.88 in) D, 10.8 kg (381.0 oz) (main unit only) |
Included Accessories | Instruction manual × 1, Application disk (Wave viewer Wv, Communication commands table) × 1, Power cord × 1 |
ACCESSORIES
CLAMP ON PROBE 3275
- DC to 2MHz (-3dB)
- 500Arms maximum input
- 0.01V/A output
- φ 20 mm (0.79 in) core dia.
CLAMP ON PROBE 3274
- DC to 10MHz (-3dB)
- 150Arms maximum input
- 0.01V/A output
- φ 20 mm (0.79 in) core dia.
CLAMP ON PROBE 3276
- DC to 100MHz (-3dB)
- 30Arms maximum input
- 0.1V/A output
- φ 5 mm (0.20 in) core dia.
CLAMP ON PROBE 3273-50
- DC to 50MHz (-3dB)
- 30Arms maximum input
- 0.1V/A output
- φ 5 mm (0.20 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
- DC to 5 kHz (-3dB)
- Rated 600 A AC/DC
- φ 33 mm (1.30 in) core dia
DISPLAY UNIT CM7290
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
- DC to 5 kHz (-3dB)
- Rated 100 A AC/DC
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
AC/DC CURRENT SENSOR CT7636
- DC to 10kHz (-3dB)
- Rated 600 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7631
- DC to 10kHz (-3dB)
- Rated 100 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
DISPLAY UNIT CM7291 (Bluetooth)
- Built in Bluetooth Smart
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
CLAMP ON SENSOR 9272-05
- 1Hz to 100kHz (Phase: 5Hz to 50kHz)
- Rated 20A/200A AC/DC
- φ 46 mm (1.81 in) core dia.
AC/DC CURRENT PROBE CT6843-05
- DC to 500kHz (Phase: up to 300kHz)
- Rated 200A AC/DC • φ 20 mm (0.79 in) core dia.
AC/DC CURRENT PROBE CT6841-05
- DC to 1MHz (Phase: up to 300kHz)
- Rated 20A AC/DC
- φ 20 mm (0.79 in) core dia.
AC/DC CURRENT SENSOR CT6863-05
- DC to 500kHz (Phase: up to 300kHz)
- Rated 200A AC/DC
- φ 24 mm (0.94 in) core dia.
AC/DC CURRENT SENSOR CT6862-05
- DC to 1MHz (Phase: up to 300kHz)
- Rated 50A AC/DC
- φ 24 mm (0.94 in) core dia.
DIFFERENTIAL PROBE P9000
- Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02)
- For use with input of up to 1 kV AC/DC
- Requires separate power supply
AC ADAPTER Z1008
- 100 to 240V AC
CONNECTION CORD L9790
- Flexible φ 4.1 mm (0.16 in) thin dia.
- Cable allowing for up to 600 V input
- 1.8 m (5.91 ft) length
ALLIGATOR CLIP L9790-01
- Red/black set attaches to the ends of the Connection Cord
L9790
GRABBER CLIP 9790-02
- Red/black set attaches to the ends of the Connection Cord L9790
CONTACT PIN 9790-03
- Red/black set attaches to the ends of the Connection Cord L9790
CONNECTION CORD L9197
- φ 5.0 mm (0.20 in) dia
- Cable allows for up to 600 V input
- 1.8 m (5.91 ft) length
- Includes detachable large alligator clips
CONNECTION CORD L9198
- φ 5.0 mm (0.20 in) dia.
- Cable allows for up to 300 V input
- 1.7 m (5.58 ft) length
- Small alligator clip
AC ADAPTER 9418-15
- 100 to 240V AC
DIFFERENTIAL PROBE 9322
- For up to 2 kV DC or 1 kV AC
- Use with AC Adapter 9418-15
- Frequency band width up to 10MHz
MAGNETIC ADAPTER SET L4937
- Attaches to the tip of the banana plug cable, CAT III 1000V
BUS BAR CLIP SET L4936
- Attaches to the tip of the banana plug cable, CAT III 600V
ALLIGATOR CLIP SET L4935
- Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
CONNECTION CABLE SET L4940
- Banana plug - banana plug, 1.5 m (4.92 ft) length, red/black each 1
TEST LEAD L2200
- 70 cm (2.30ft) length, detachable large alligator clips or needle tips are bundled, CAT IV 600V, CAT III 1000V0
- 1 kV rms Max. (500 kHz or less)
- Max. rated voltage to earth depends on input unit.
GRABBER CLIP 9243 (196mm)
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length
100:1 PROBE, 10:1 PROBE 9666, 9665
- Max. rated voltage to earth is same as for input module
- 1.5 m (4.92 ft) length
- Max. input voltage: 9666: 5 kV peak (up to 1MHz); 9665: 1 kV rms (up to 500 kHz)
OUTPUT CORD L9095
- Connect to BNC terminal, 1.5 m (4.92 ft) length
CONVERSION CABLE 9323
- Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models
LOGIC PROBE MR9321,MR9321-01
- 4 isolated channels
- ON/OFF detection of AC/DC voltage
- Large terminal type
LOGIC PROBE 9327
- 4 channels for contact voltage signals
- High-speed 100ns response
POWER SUPPLY 3269
- For Hioki wide bandwidth current probes
- Connect up to four sensors
CONVERSION CABLE CT9901
- ME15W (12 pin) to PL23 (10 pin) connector
CONVERSION ADAPTER 9199
- Receiving side banana, output BNC terminal
CONVERSION CABLE 9318
- To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length
CONNECTION CORD 9165
- Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
CONNECTION CABLE L9795-02
- SMB to BNC terminal, 1.5 m (4.92 ft) length
CONNECTION CABLE L9795-01
- SMB to alligator clip, 1.5 m (4.92 ft) length
WAVEFORM GENERATOR UNIT MR8790
- 4 ch
- DC output ± 10 V
- Sinewave output 10 mHz to 20 kHz
PULSE GENERATOR UNIT MR8791
- 8 ch
- Pulse output 0.1 Hz to 20 kHz
- Pattern output
ARBITRARY WAVEFORM GENERATOR UNIT U8793
- 2ch, 10 mHz to 100kHz function generator
- Arbitrary waveform generator function 2 MHz D/A refresh rate
- Max.15 V output
LAN COMMUNICATOR 9333
- For LAN communication with the MR8740/8741, MR8847 series, 8826
- For data collection and remote control
WAVE PROCESSOR 9335
- Convert data, print and display waveforms
LAN CABLE 9642
- Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
CONVERSION CABLE CT9900
- Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal
STRAIN UNIT U8969
- 2 ch, acceleration, load, pressure or strain
- Strain gauge converter amp
DIGITAL VOLTMETER UNIT MR8990
- 2 ch, high-precision DC V, 0.1 μV resolution, high-speed sampling 500 times/s
LOGIC UNIT 8973
- 4 terminals, 16 ch
DC/RMS UNIT 8972
- 2 ch, voltage/DC to 400 kHz, RMS rectifier, DC and 30 to 100 kHz bandwidth
CURRENT UNIT 8971
- 2 ch, for measuring current using dedicated current sensors, bundled two Conversion cable 9318
FREQ UNIT 8970
- 2 ch, for measurement of frequency, rpm, pulse, etc.
HIGH RESOLUTION UNIT 8968
- 2 ch, voltage input, DC to 100 kHz bandwidth
TEMP UNIT 8967
- 2 ch, thermocouple temperature input
ANALOG UNIT 8966
- 2 ch, Voltage input, DC to 5 MHz bandwidth
POWER SUPPLY 3272
- For Hioki wide bandwidth current probes
- Single sensor connectable
AC ADAPTER Z1008
- 100 to 240V AC
SENSOR UNIT CT9556
- Power supply for current sensors when used alone
- 1ch, with Waveform/RMS output
SENSOR UNIT CT9555
- Power supply for current sensors when used alone
- 1ch, with Waveform output
SENSOR UNIT CT9557
- Power supply for current sensors when used alone
- 4ch, with Waveform/Total Waveform/Total RMS output
USB DRIVE Z4006
- 16 GB, Long-life, High-reliability SLC Flash Memory
AC/DC CURRENT PROBE CT6846-05
- DC to 20kHz (Phase: up to 20kHz)
- Rated 1000A AC/DC
- φ 50 mm (1.79 in) core dia.
SENSOR UNIT CT9557
- Power supply for current sensors when used alone
- 4ch, with Waveform/Total Waveform/Total RMS output
AC/DC CURRENT PROBE CT6844-05
- DC to 200kHz (Phase: up to 200kHz)
- Rated 500A AC/DC • φ 20 mm (0.79 in) core dia.
EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
CLAMP ON PROBE 3275
- DC to 2MHz (-3dB)
- 500Arms maximum input
- 0.01V/A output
- φ 20 mm (0.79 in) core dia.
CLAMP ON PROBE 3274
- DC to 10MHz (-3dB)
- 150Arms maximum input
- 0.01V/A output
- φ 20 mm (0.79 in) core dia.
CLAMP ON PROBE 3276
- DC to 100MHz (-3dB)
- 30Arms maximum input
- 0.1V/A output
- φ 5 mm (0.20 in) core dia.
CLAMP ON PROBE 3273-50
- DC to 50MHz (-3dB)
- 30Arms maximum input
- 0.1V/A output
- φ 5 mm (0.20 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
- DC to 5 kHz (-3dB)
- Rated 600 A AC/DC
- φ 33 mm (1.30 in) core dia
DISPLAY UNIT CM7290
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
- DC to 5 kHz (-3dB)
- Rated 100 A AC/DC
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
AC/DC CURRENT SENSOR CT7636
- DC to 10kHz (-3dB)
- Rated 600 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7631
- DC to 10kHz (-3dB)
- Rated 100 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
DISPLAY UNIT CM7291 (Bluetooth)
- Built in Bluetooth Smart
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
CLAMP ON SENSOR 9272-05
- 1Hz to 100kHz (Phase: 5Hz to 50kHz)
- Rated 20A/200A AC/DC
- φ 46 mm (1.81 in) core dia.
AC/DC CURRENT PROBE CT6843-05
- DC to 500kHz (Phase: up to 300kHz)
- Rated 200A AC/DC • φ 20 mm (0.79 in) core dia.
AC/DC CURRENT PROBE CT6841-05
- DC to 1MHz (Phase: up to 300kHz)
- Rated 20A AC/DC
- φ 20 mm (0.79 in) core dia.
AC/DC CURRENT SENSOR CT6863-05
- DC to 500kHz (Phase: up to 300kHz)
- Rated 200A AC/DC
- φ 24 mm (0.94 in) core dia.
AC/DC CURRENT SENSOR CT6862-05
- DC to 1MHz (Phase: up to 300kHz)
- Rated 50A AC/DC
- φ 24 mm (0.94 in) core dia.
DIFFERENTIAL PROBE P9000
- Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02)
- For use with input of up to 1 kV AC/DC
- Requires separate power supply
AC ADAPTER Z1008
- 100 to 240V AC
CONNECTION CORD L9790
- Flexible φ 4.1 mm (0.16 in) thin dia.
- Cable allowing for up to 600 V input
- 1.8 m (5.91 ft) length
ALLIGATOR CLIP L9790-01
- Red/black set attaches to the ends of the Connection Cord
L9790
GRABBER CLIP 9790-02
- Red/black set attaches to the ends of the Connection Cord L9790
CONTACT PIN 9790-03
- Red/black set attaches to the ends of the Connection Cord L9790
CONNECTION CORD L9197
- φ 5.0 mm (0.20 in) dia
- Cable allows for up to 600 V input
- 1.8 m (5.91 ft) length
- Includes detachable large alligator clips
CONNECTION CORD L9198
- φ 5.0 mm (0.20 in) dia.
- Cable allows for up to 300 V input
- 1.7 m (5.58 ft) length
- Small alligator clip
AC ADAPTER 9418-15
- 100 to 240V AC
DIFFERENTIAL PROBE 9322
- For up to 2 kV DC or 1 kV AC
- Use with AC Adapter 9418-15
- Frequency band width up to 10MHz
MAGNETIC ADAPTER SET L4937
- Attaches to the tip of the banana plug cable, CAT III 1000V
BUS BAR CLIP SET L4936
- Attaches to the tip of the banana plug cable, CAT III 600V
ALLIGATOR CLIP SET L4935
- Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
CONNECTION CABLE SET L4940
- Banana plug - banana plug, 1.5 m (4.92 ft) length, red/black each 1
TEST LEAD L2200
- 70 cm (2.30ft) length, detachable large alligator clips or needle tips are bundled, CAT IV 600V, CAT III 1000V0
- 1 kV rms Max. (500 kHz or less)
- Max. rated voltage to earth depends on input unit.
GRABBER CLIP 9243 (196mm)
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length
100:1 PROBE, 10:1 PROBE 9666, 9665
- Max. rated voltage to earth is same as for input module
- 1.5 m (4.92 ft) length
- Max. input voltage: 9666: 5 kV peak (up to 1MHz); 9665: 1 kV rms (up to 500 kHz)
OUTPUT CORD L9095
- Connect to BNC terminal, 1.5 m (4.92 ft) length
CONVERSION CABLE 9323
- Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models
LOGIC PROBE MR9321,MR9321-01
- 4 isolated channels
- ON/OFF detection of AC/DC voltage
- Large terminal type
LOGIC PROBE 9327
- 4 channels for contact voltage signals
- High-speed 100ns response
POWER SUPPLY 3269
- For Hioki wide bandwidth current probes
- Connect up to four sensors
CONVERSION CABLE CT9901
- ME15W (12 pin) to PL23 (10 pin) connector
CONVERSION ADAPTER 9199
- Receiving side banana, output BNC terminal
CONVERSION CABLE 9318
- To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length
CONNECTION CORD 9165
- Cord has metallic BNC connectors at both ends, use at metallic terminal, 1.5 m (4.92 ft) length
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
CONNECTION CABLE L9795-02
- SMB to BNC terminal, 1.5 m (4.92 ft) length
CONNECTION CABLE L9795-01
- SMB to alligator clip, 1.5 m (4.92 ft) length
WAVEFORM GENERATOR UNIT MR8790
- 4 ch
- DC output ± 10 V
- Sinewave output 10 mHz to 20 kHz
PULSE GENERATOR UNIT MR8791
- 8 ch
- Pulse output 0.1 Hz to 20 kHz
- Pattern output
ARBITRARY WAVEFORM GENERATOR UNIT U8793
- 2ch, 10 mHz to 100kHz function generator
- Arbitrary waveform generator function 2 MHz D/A refresh rate
- Max.15 V output
LAN COMMUNICATOR 9333
- For LAN communication with the MR8740/8741, MR8847 series, 8826
- For data collection and remote control
WAVE PROCESSOR 9335
- Convert data, print and display waveforms
LAN CABLE 9642
- Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
CONVERSION CABLE CT9900
- Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal
STRAIN UNIT U8969
- 2 ch, acceleration, load, pressure or strain
- Strain gauge converter amp
DIGITAL VOLTMETER UNIT MR8990
- 2 ch, high-precision DC V, 0.1 μV resolution, high-speed sampling 500 times/s
LOGIC UNIT 8973
- 4 terminals, 16 ch
DC/RMS UNIT 8972
- 2 ch, voltage/DC to 400 kHz, RMS rectifier, DC and 30 to 100 kHz bandwidth
CURRENT UNIT 8971
- 2 ch, for measuring current using dedicated current sensors, bundled two Conversion cable 9318
FREQ UNIT 8970
- 2 ch, for measurement of frequency, rpm, pulse, etc.
HIGH RESOLUTION UNIT 8968
- 2 ch, voltage input, DC to 100 kHz bandwidth
TEMP UNIT 8967
- 2 ch, thermocouple temperature input
ANALOG UNIT 8966
- 2 ch, Voltage input, DC to 5 MHz bandwidth
POWER SUPPLY 3272
- For Hioki wide bandwidth current probes
- Single sensor connectable
AC ADAPTER Z1008
- 100 to 240V AC
SENSOR UNIT CT9556
- Power supply for current sensors when used alone
- 1ch, with Waveform/RMS output
SENSOR UNIT CT9555
- Power supply for current sensors when used alone
- 1ch, with Waveform output
SENSOR UNIT CT9557
- Power supply for current sensors when used alone
- 4ch, with Waveform/Total Waveform/Total RMS output
USB DRIVE Z4006
- 16 GB, Long-life, High-reliability SLC Flash Memory
AC/DC CURRENT PROBE CT6846-05
- DC to 20kHz (Phase: up to 20kHz)
- Rated 1000A AC/DC
- φ 50 mm (1.79 in) core dia.
SENSOR UNIT CT9557
- Power supply for current sensors when used alone
- 4ch, with Waveform/Total Waveform/Total RMS output
AC/DC CURRENT PROBE CT6844-05
- DC to 200kHz (Phase: up to 200kHz)
- Rated 500A AC/DC • φ 20 mm (0.79 in) core dia.
EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
DOWNLOADS
Catalog
- MEMORY HiCORDER MR8740, MR8741
Declaration of Conformity
- MEMORY HiCORDER MR8740,MR8741
Catalog
- MEMORY HiCORDER MR8740, MR8741
Declaration of Conformity