Memory HiLogger LR8450
Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The LR8450 offers 1 ms sampling across up to 120 channels, and can be paired with 5 different types of plug-in input units. New input modules measure strain and distortion, ideal for automotive applications involving the evaluation of vehicle components as well as robotic equipment.
Key Features
- Expandable to 120 ch with wired/plug-in units
- Record voltage output from pressure and other sensors with 1ms sampling speed
- Directly connect strain gauge and measure signals in as fast as 1ms intervals
- Significantly reduced effects from noise let you safely measure in high voltage and high frequency areas such as around inverter motors
Product Warranty Period: 3 years
Included Accessories:
Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1
Key Features
- Expandable to 120 ch with wired/plug-in units
- Record voltage output from pressure and other sensors with 1ms sampling speed
- Directly connect strain gauge and measure signals in as fast as 1ms intervals
- Significantly reduced effects from noise let you safely measure in high voltage and high frequency areas such as around inverter motors
Product Warranty Period: 3 years
Included Accessories:
Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1
Max. number of connectable modules | 4 plug-in input modules |
---|---|
Connectable modules (Plug-in modules) | U8550, U8551, U8552, U8553, U8554 |
No. of measurement channels | Up to 120 ch with plug-in input modules |
Pulse/logic input | [Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels) [Adaptive input format] Non-voltage contact, open collector, or voltage input [Count] 0 to 1000 M pulse, 1 pulse resolution [Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000) [Logic input] Records 1 or 0 for each recording interval |
Recording intervals | 1 ms*, 2 ms*, 5 ms* (*: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each unit |
Data storage | SD Memory Card/USB Drive (user-selectable) (Only storage media sold by HIOKI are guaranteed for operation) |
LAN interface | 100BASE-TX / 1000BASE-T, DHCP, DNS support, Functions: Data acquisition, condition settings used with the Logger Utility software, configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, NTP client |
USB interface | Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub) Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer |
SD card slot | SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: Z4001, Z4003 |
Display | 7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel) |
Functions | Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable) |
Power supply | [AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter) [Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max. [External power] 10 to 30 V DC, 28 VA Max. (Please contact your HIOKI distributor for connection cord) |
Dimensions and mass | Without any modules: 272 mm (10.71 in) W × 145 mm (5.71 in) H × 43 mm (1.69 in) D (excluding protrusions), 1108 g (39.1 oz) (excluding battery pack) With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D (excluding protrusions) With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D (excluding protrusions) |
Included Accessories | Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1 |
ACCESSORIES
CARRYING CASE C1012
- Includes space for options
FIXED STAND Z5040
- For installing logger on wall
- HUMIDITY SENSOR Z20003 m (9.84 ft) length
LAN CABLE 9642
- Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
VOLTAGE/TEMP UNIT U8550
- Voltage, thermocouple, humidity measurement, 15 ch, 10 ms sampling
UNIVERSAL UNIT U8551
- Voltage, thermocouple, humidity, Pt100/1000, JPt100, Resistance measurement, 15 ch, 10 ms sampling
VOLTAGE/TEMP UNIT U8552
- Voltage, thermocouple, humidity measurement, 30 ch, 20 ms sampling, 10 ms when the number of channels used is 15 or less
STRAIN UNIT U8554
- Strain, voltage, strain gauge transducer, 5 ch, 1 ms sampling
HIGH SPEED VOLTAGE UNIT U8553
- Voltage, 5 ch, 1 ms sampling
BATTERY PACK Z1007
- Li-ion, Charges while installed
AC Adapter Z1014
- 100 to 240 V AC
SD MEMORY CARD 2GB Z4001
- 2 GB capacity
SD MEMORY CARD Z4003
- 8 GB capacity
USB DRIVE Z4006
- 16 GB, Long-life, High-reliability SLC Flash Memory
CARRYING CASE C1012
- Includes space for options
FIXED STAND Z5040
- For installing logger on wall
- HUMIDITY SENSOR Z20003 m (9.84 ft) length
LAN CABLE 9642
- Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
VOLTAGE/TEMP UNIT U8550
- Voltage, thermocouple, humidity measurement, 15 ch, 10 ms sampling
UNIVERSAL UNIT U8551
- Voltage, thermocouple, humidity, Pt100/1000, JPt100, Resistance measurement, 15 ch, 10 ms sampling
VOLTAGE/TEMP UNIT U8552
- Voltage, thermocouple, humidity measurement, 30 ch, 20 ms sampling, 10 ms when the number of channels used is 15 or less
STRAIN UNIT U8554
- Strain, voltage, strain gauge transducer, 5 ch, 1 ms sampling
HIGH SPEED VOLTAGE UNIT U8553
- Voltage, 5 ch, 1 ms sampling
BATTERY PACK Z1007
- Li-ion, Charges while installed
AC Adapter Z1014
- 100 to 240 V AC
SD MEMORY CARD 2GB Z4001
- 2 GB capacity
SD MEMORY CARD Z4003
- 8 GB capacity
USB DRIVE Z4006
- 16 GB, Long-life, High-reliability SLC Flash Memory
DOWNLOADS
Catalog
- MEMORY HiLOGGER LR8450
Declaration of Conformity
- MEMORY HiLOGGER LR8450,LR8450-01
Selection Guide
- Data Loggers Selection Guide (LR8450, LR8450-01, LR8410-20, LR8431-20, 8423)
Catalog
- MEMORY HiLOGGER LR8450
Declaration of Conformity
- MEMORY HiLOGGER LR8450,LR8450-01
Selection Guide
- Data Loggers Selection Guide (LR8450, LR8450-01, LR8410-20, LR8431-20, 8423)