Memory HiCorder MR6000

(0) No Reviews yet
$14,960.00
SKU: MR6000
Ships in approximately 60 days if not in stock.

Contact for Lead Time

The MR6000 overcomes all barriers to reach new ground and meet challenges that are yet to be seen. World class specifications, operability and design - Hioki's newest memory recorder has been re-engineered from top to bottom, delivering unprecedented performance that will change how you look at waveform recording.


Key Features
- Work efficiently and intuitively using the MR6000s large touch panel
- Capture momentary phenomena by performing isolation measurement at up to 200 MS/s (when using the High Speed Analog Unit U8976)
- Enjoy a stress-free user experience thanks to dramatically faster saving of data
- Save data in real time while measurement continues.
- Take advantage of new functionality added by the latest firmware update (April 2020)

Product Warranty Period: 3 years

Included Accessories:
Power cord ×1, Quick start manual ×1, Precautions conserning use ×1, Application disk (CD-R) ×1, Instruction manual (CD-R, detail and calculation) ×1 , Blank panel (for blank slots only)

MR6000MR6000-01
Additional functionN/AReal-time waveform calculation, Digital Filter calculation
Number of input unitsMax. 8 units
Number of channelsMax. 32 analog channels (when using the U8975), or 128 logic channels (when using the 8973)
Measurement ranges (20 div full-scale)10 mV to 400 V f.s., 12 ranges (when using the U8976), Resolution : 1/1600 of range
4 V to 200 V f.s., 6 ranges (when using the U8975), Resolution : 1/32000 of range
Max. allowable input400 V DC (when using the U8976), 200 V DC (when using the U8975)
Frequency characteristicsDC to 30 MHz (when using the U8976), DC to 2 MHz (when using the U8975)
Max. sampling rate200 MS/s, all channnels simultaneously (when using the U8976)
External sampling: 10 MS/s
Recording methodsNormal: Normal waveform recording
Envelope: Record maximum and minimum values every fixed period
Storage memory capacity1 G-words
Removable storageSD memory card ×1, USB memory ×7, SSD/HDD (built in the main unit) ×1
FTP transmission (to LAN-connected computer) *Use only Storage Media sold by HIOKI.
Display12.1 inch XGA-TFT color LCD (1024 × 768 dots)
External interfacesLAN, USB, SD, SATA, Monitor output
Power supply100 to 240 V AC (50/60 Hz) (300 VA max.)
Dimensions and mass353 mm (13.9 in)W × 235 mm (9.25 in)H × 154.8 mm (6.09 in)D, 6.5 kg (229.3 oz) (main unit only)
Included AccessoriesPower cord ×1, Quick start manual ×1, Precautions conserning use ×1, Application disk (CD-R) ×1, Instruction manual (CD-R, detail and calculation) ×1 , Blank panel (for blank slots only)

ACCESSORIES



CLAMP ON PROBE 3275
- DC to 2MHz (-3dB)
- 500Arms maximum input 
- 0.01V/A output 
- φ 20 mm (0.79 in) core dia.



CLAMP ON PROBE 3274
- DC to 10MHz (-3dB) 
- 150Arms maximum input 
- 0.01V/A output 
- φ 20 mm (0.79 in) core dia.



CLAMP ON PROBE 3276
- DC to 100MHz (-3dB) 
- 30Arms maximum input 
- 0.1V/A output 
- φ 5 mm (0.20 in) core dia.



CLAMP ON PROBE 3273-50
- DC to 50MHz (-3dB) 
- 30Arms maximum input 
- 0.1V/A output 
- φ 5 mm (0.20 in) core dia.



CARRYING CASE C1010
- For the MR6000, hard trunk type, for storing options




CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length



SSD UNIT U8332
- Specified upon order, built-in type, 256 GB



HD UNIT U8333
- Specified upon order, built-in type, 320 GB



CLAMP ON SENSOR 9272-05
- 1Hz to 100kHz (Phase: 5Hz to 50kHz) 
- Rated 20A/200A AC/DC 
- φ 46 mm (1.81 in) core dia.



AC/DC CURRENT PROBE CT6843-05
- DC to 500kHz (Phase: up to 300kHz) 
- Rated 200A AC/DC 
- φ 20 mm (0.79 in) core dia.



AC/DC CURRENT PROBE CT6841-05
- DC to 1MHz (Phase: up to 300kHz) 
- Rated 20A AC/DC 
- φ 20 mm (0.79 in) core dia.



AC/DC CURRENT SENSOR CT6863-05
- DC to 500kHz (Phase: up to 300kHz) 
- Rated 200A AC/DC 
- φ 24 mm (0.94 in) core dia.



AC/DC CURRENT SENSOR CT6862-05
- DC to 1MHz (Phase: up to 300kHz) 
- Rated 50A AC/DC 
- φ 24 mm (0.94 in) core dia.



DIFFERENTIAL PROBE P9000
- Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02)

- For use with input of up to 1 kV AC/DC 
- Requires separate power supply



AC ADAPTER Z1008
- 100 to 240V AC



CONNECTION CORD L9790
- Flexible φ 4.1 mm (0.16 in) thin dia. 
- Cable allowing for up to 600 V input 
- 1.8 m (5.91 ft) length



ALLIGATOR CLIP L9790-01
- Red/black set attaches to the ends of the Connection Cord L9790



GRABBER CLIP 9790-02
- Red/black set attaches to the ends of the Connection Cord L9790



CONTACT PIN 9790-03
- Red/black set attaches to the ends of the Connection Cord L9790



CONNECTION CORD L9197
- φ 5.0 mm (0.20 in) dia 
- Cable allows for up to 600 V input 
- 1.8 m (5.91 ft) length 
- Includes detachable large alligator clips



CONNECTION CORD L9198
- φ 5.0 mm (0.20 in) dia. 
- Cable allows for up to 300 V input 
- 1.7 m (5.58 ft) length 
- Small alligator clip



AC ADAPTER 9418-15
- 100 to 240V AC



DIFFERENTIAL PROBE 9322
- For up to 2 kV DC or 1 kV AC 
- Use with AC Adapter 9418-15 
- Frequency band width up to 10MHz



MAGNETIC ADAPTER SET L4937
- Attaches to the tip of the banana plug cable, CAT III 1000V



BUS BAR CLIP SET L4936
- Attaches to the tip of the banana plug cable, CAT III 600V



ALLIGATOR CLIP SET L4935
- Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V



EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length



CONNECTION CABLE SET L4940
- Banana plug - banana plug, 1.5 m (4.92 ft) length, red/black each 1



TEST LEAD L2200
- 70 cm (2.30ft) length, detachable large alligator clips or needle tips are bundled, CAT IV 600V, CAT III 1000V



100:1 PROBE, 10:1 PROBE 9666, 9665
- Max. rated voltage to earth is same as for input module 
- 1.5 m (4.92 ft) length 
- Max. input voltage: 9666: 5 kV peak (up to 1MHz); 9665: 1 kV rms (up to 500 kHz)



OUTPUT CORD L9095
- Connect to BNC terminal, 1.5 m (4.92 ft) length



OUTPUT CORD L9094
- 3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length



AC ADAPTER 9445-02
- For USA, 100 to 240 V AC, 9 V/ 1 A



LOGIC PROBE MR9321,MR9321-01
- 4 isolated channels 
- ON/OFF detection of AC/DC voltage 
- Large terminal type




LOGIC PROBE 9320-01
- 4 channels for contact voltage signals 
- 500ns response 
- Miniature terminal type



LOGIC PROBE 9327
- 4 channels for contact voltage signals 
- High-speed 100ns response



PROBE POWER UNIT Z5021
*Must specify when ordering
*Power can be supplied to up to 8 current sensors, including the current sensors connected to the CURRENT UNIT 8971.Specified upon order, DC ±12 V, supply for up to 8 units



POWER SUPPLY 3269
- For Hioki wide bandwidth current probes 
- Connect up to four sensors



CONVERSION CABLE CT9901
- ME15W (12 pin) to PL23 (10 pin) connector



GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V



CONNECTION CORD L9217

- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length



CONVERSION ADAPTER 9199
- Receiving side banana, output BNC terminal



CONVERSION CABLE 9318
- To connect the CT6841-6846, CT6865/63/62, 9709, 9272-10 to the 8971/40/51, 38 cm (14.96 in) length



CONNECTION CABLE L9795-01
- SMB to alligator clip, 1.5 m (4.92 ft) length



CONNECTION CABLE L9795-02
- SMB to BNC terminal, 1.5 m (4.92 ft) length



OUTPUT CORD L9096
- Connect to terminal block, 1.5 m (4.92 ft) length



WAVE PROCESSOR 9335
- Convert data, print and display waveforms



LAN CABLE 9642
- Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length



CONVERSION CABLE CT9900
- Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal



CHARGE UNIT U8979
- Measure acceleration waveforms across 2 channels 
- Charge output type acceleration pickup 
- Preamplifier built-in acceleration pickup



4CH ANALOG UNIT U8978
- 4 ch instantaneous waveforms 
- DC to 2 MHz bandwidth



3CH CURRENT UNIT U8977
- 3 ch, current measurement 
- DC to 2 MHz bandwidth



4CH ANALOG UNIT U8975
- 4 ch 
- DC to 2 MHz bandwidth



HIGH SPEED ANALOG UNIT U8976
- 2 ch 
- DC to 30 MHz bandwidth




HIGH VOLTAGE UNIT U8974
- 2 ch, 1000 V DC, 700 V AC max. voltage input



DIGITAL VOLTMETER UNIT MR8990
- 2 ch, high-precision DC V, 0.1 μV resolution, high-speed sampling 500 times/s



LOGIC UNIT 8973
- 4 terminals, 16 ch



DC/RMS UNIT 8972
- 2 ch, voltage/DC to 400 kHz, RMS rectifier, DC and 30 to 100 kHz bandwidth



CURRENT UNIT 8971
- 2 ch, for measuring current using dedicated current sensors, bundled two Conversion cable 9318



FREQ UNIT 8970
- 2 ch, for measurement of frequency, rpm, pulse, etc.



HIGH RESOLUTION UNIT 8968
- 2 ch, voltage input, DC to 100 kHz bandwidth



TEMP UNIT 8967
- 2 ch, thermocouple temperature input



ANALOG UNIT 8966
- 2 ch, Voltage input, DC to 5 MHz bandwidth



POWER SUPPLY 3272
- For Hioki wide bandwidth current probes 
- Single sensor connectable



AC ADAPTER Z1008
- 100 to 240V AC



SENSOR UNIT CT9557
- Power supply for current sensors when used alone 
- 4ch, with Waveform/Total Waveform/Total RMS output



SENSOR UNIT CT9556
- Power supply for current sensors when used alone 
- 1ch, with Waveform/RMS output



SENSOR UNIT CT9555
- Power supply for current sensors when used alone 
- 1ch, with Waveform output



USB DRIVE Z4006
- 16 GB, Long-life, High-reliability SLC Flash Memory



SD MEMORY CARD Z4003
- 8 GB capacity



SD MEMORY CARD 2GB Z4001
- 2 GB capacity




AC/DC CURRENT PROBE CT6846-05
- DC to 20kHz (Phase: up to 20kHz) 
- Rated 1000A AC/DC 
- φ 50 mm (1.79 in) core dia.



AC/DC CURRENT SENSOR CT6876
- DC to 1.5MHz (Phase: up to 1MHz) 
- Rated 1000A AC/DC 
- φ 36 mm (1.42 in) core dia.



AC/DC CURRENT PROBE CT6846-05
- DC to 20kHz (Phase: up to 20kHz)
- Rated 1000A AC/DC 
- φ 50 mm (1.79 in) core dia.



AC/DC CURRENT SENSOR CT6876
- DC to 1.5MHz (Phase: up to 1MHz) 
- Rated 1000A AC/DC 
- φ 36 mm (1.42 in) core dia.



SENSOR UNIT CT9557
- Power supply for current sensors when used alone 
- 4ch, with Waveform/Total Waveform/Total RMS output




AC/DC CURRENT SENSOR CT6876
- DC to 1.5MHz (Phase: up to 1MHz) 
- Rated 1000A AC/DC 
- φ 36 mm (1.42 in) core dia.




AC/DC CURRENT PROBE CT6845-05
- DC to 100kHz (Phase: up to 100kHz) 
- Rated 500A AC/DC 
- φ 50 mm (1.97 in) core dia.



AC/DC CURRENT PROBE CT6844-05
- DC to 200kHz (Phase: up to 200kHz) 
- Rated 500A AC/DC 
- φ 20 mm (0.79 in) core dia.



AC/DC CURRENT SENSOR CT6875
- DC to 2MHz (Phase: up to 1MHz) 
- Rated 500A AC/DC 
- φ 36 mm (1.42 in) core dia.



GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V



EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length

DOWNLOADS

Catalog
MEMORY HiCORDER MR6000

Declaration of Conformity
MEMORY HiCORDER MR6000,MR6000-01

OPTIONS


MR6000-01
- Built-in real-time waveform calculation and other functionality

Ratings & Reviews

No reviews available

Be the first to Write a Review