Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW3390 is a high-precision, broad-range power analyzer for measuring electrical power from DC to inverter frequencies, providing four input channels to support single- and three-phase inverter motor systems up to 4000 A AC/DC with superior accuracy.

Key Features
- ±0.04% basic power accuracy, among the best in its class
- 200 kHz measurement band with flat amplitude and phase accuracy that extend to high frequencies
- Remarkably small and light footprint, enabling high-accuracy measurement to be easily carried out even in the field
- High-accuracy, high-speed calculation of transient-state power in 50 ms; harmonic analysis; display of instantaneous waveforms; noise analysis; and simultaneous parallel calculation of all parameters, including efficiency loss
- Send measured values to HIOKI data loggers using a Bluetooth wireless technology compatible adapter (LR8410 Link-compatible products)
- Simultaneous measurement of multiple circuits and ability to acquire synchronized data using up to 8 devices (for 32 channels)
 Simple power measurement using clamp-on current sensors
- Measurement of current and power inputs and outputs as part of the new WLTP fuel efficiency international standard


Included Accessories:
Instruction Manual ×1, Power cord ×1, Measurement Guide ×1, USB cable ×1, Input cord label ×2, D-sub connector × 1 (PW3390-02, PW3390-03)
Measurement line typeSingle-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel
Measurement itemsFrequency, RMS voltage, voltage mean value rectification RMS equivalent, voltage AC component, voltage simple average, voltage fundamental wave component, voltage waveform peak +, voltage waveform peak -, voltage total harmonic distortion, voltage ripple factor, voltage unbalance factor, RMS current, current mean value rectification RMS equivalent, current AC component, current simple average, current fundamental wave component, current waveform peak +, current waveform peak -, current total harmonic distortion, current ripple factor, current unbalance factor, active power, apparent power, reactive power, power factor, voltage phase angle current phase angle, power phase angle, positive-direction current magnitude, negative-direction current magnitude, sum of positive- and negative-direction current magnitude, positive-direction power magnitude, negative-direction power magnitude, sum of positive- and negative-direction power magnitude, efficiency, loss
Current integration, active power integration
PW3390-03 only: Torque, Rotation, Frequency, Slip, or Motor power
Harmonic measurementInput: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz,
Number of harmonic orders: Max. 100th order
Noise measurementNumber of channels: 1 ch (select one channel from CH1 to CH4),
Maximum analysis frequency: 200 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz
Motor Analysis (PW3390-03 only)Input: 3 ch (CH A, CH B, CH Z), Measurement parameters: Voltage, torque, rotation rate, frequency, slip, and motor power
Measurement rangeVoltage range: 15 to 1500 V, 7 ranges
Current range: 0.1 A to 20 kA (depends on current sensor)
Effective measuring power range0.0150 W to 39.600 MW (determined automatically by the combination of voltage range, current range, and measurement line)
Basic accuracy (45 to 66 Hz)Voltage: ±0.04 % rdg. ±0.05 % f.s.
Current: ±0.04 % rdg. ±0.05 % f.s. + current sensor accuracy
Active power: ±0.04 % rdg. ±0.05 % f.s. + current sensor accuracy
Synchronization frequency range0.5 Hz to 5 kHz
Frequency bandDC, 0.5 Hz to 200 kHz
Data update rate50 ms (For harmonic/frequency measurement, depends on the synchronization frequency when less than 45 Hz)
Display refresh rate200 ms (Independent of internal data update rate; waveform and FFT depend on the screen)
Auto-Save FunctionsEach value is stored to CF card during every measurement interval (not available for USB storage), OFF, 50 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes, 15 settings
External interfacesLAN, USB (for communication/ memory), RS-232C (for communication/LR8410 link), CF card, Synchronization control, External Control
Logger connectivitySends measured values wirelessly to logger by using a BluetoothⓇ wireless technology serial conversion adapter. (Supported devices: Hioki LR8410 Link-compatible loggers)
Power supply100 to 240 V AC, 50/60 Hz, 140 VA max.
Dimensions and mass340 mm (13.39 in)W × 170 mm (6.69 in)H × 156 mm (6.14 in)D, 4.6 kg (162.3 oz)
Included AccessoriesInstruction Manual ×1, Power cord ×1, Measurement Guide ×1, USB cable ×1, Input cord label ×2, D-sub connector × 1 (PW3390-02, PW3390-03)

ACCESSORIES



AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB) 
- Rated 2000 A AC/DC 
- 0.1mV/A output 
- φ 55 mm (2.17 in) core dia.



AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB) 
- Rated 2000 A AC/DC 
- φ 55 mm (2.17 in) core dia.




CARRYING CASE 9794
- Hard trunk type



CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length



CONNECTION CABLE 9683
- For synchronization, cable length 1.5 m (4.92 ft)



CONVERSION CABLE CT9920
- Required to connect the PW3390 or other instrument’s ME15W terminal to a current sensor with a PL14 output connector.



AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB) 
- Rated 2000 A AC/DC 
- 0.1mV/A output 
- φ 55 mm (2.17 in) core dia.



AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB) 
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.



CONVERSION CABLE CT9920
- Required to connect the PW3390 or other instrument’s ME15W terminal to a current sensor with a PL14 output connector.



AC/DC CURRENT SENSOR CT6862-05
- DC to 1MHz (Phase: up to 300kHz) 
- Rated 50A AC/DC 
- φ 24 mm (0.94 in) core dia.



AC/DC CURRENT SENSOR CT6863-05
- DC to 500kHz (Phase: up to 300kHz) 
- Rated 200A AC/DC 
- φ 24 mm (0.94 in) core dia.



AC/DC CURRENT PROBE CT6841-05
- DC to 1MHz (Phase: up to 300kHz) 
- Rated 20A AC/DC 
- φ 20 mm (0.79 in) core dia.




AC/DC CURRENT PROBE CT6843-05
- DC to 500kHz (Phase: up to 300kHz) 
- Rated 200A AC/DC 
- φ 20 mm (0.79 in) core dia.



CLAMP ON SENSOR 9272-05
- 1Hz to 100kHz (Phase: 5Hz to 50kHz) 
- Rated 20A/200A AC/DC 
- φ 46 mm (1.81 in) core dia.



EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length



LAN CABLE 9642
- Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length



GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V



CONNECTION CABLE 9683
- For synchronization, cable length 1.5 m (4.92 ft)



CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length



RS-232C CABLE 9637
- For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length



CONVERSION CABLE CT9900
- Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal



SENSOR UNIT CT9557
- Power supply for current sensors when used alone 
- 4ch, with Waveform/Total Waveform/Total RMS output



PC CARD 1G 9729
- 1 GB capacity 
- PC card adapter bundled



PC CARD 9830
- 2 GB capacity 
- PC card adapter bundled



PC CARD 512M 9728
- 512 MB capacity 
- PC card adapter bundled



AC/DC CURRENT SENSOR CT6876
- DC to 1.5MHz (Phase: up to 1MHz) 
- Rated 1000A AC/DC 
- φ 36 mm (1.42 in) core dia.




AC/DC CURRENT PROBE CT6846-05
- DC to 20kHz (Phase: up to 20kHz) 
- Rated 1000A AC/DC 
- φ 50 mm (1.79 in) core dia.



AC/DC CURRENT PROBE CT6846-05
- DC to 20kHz (Phase: up to 20kHz) 
- Rated 1000A AC/DC 
- φ 50 mm (1.79 in) core dia.



AC/DC CURRENT SENSOR CT6876
- DC to 1.5MHz (Phase: up to 1MHz) 
- Rated 1000A AC/DC
- φ 36 mm (1.42 in) core dia.



AC/DC CURRENT PROBE CT6846-05
- DC to 20kHz (Phase: up to 20kHz) 
- Rated 1000A AC/DC 
- φ 50 mm (1.79 in) core dia.



AC/DC CURRENT SENSOR CT6877
- DC to 1 MHz (Phase: up to 700kHz) 
- Rated 2000A AC/DC 
- φ 80 mm (3.15 in) core dia.



CONNECTION CABLE CT9904
- ME15W (12 pin) terminal to ME15W (12 pin) terminal, 1 m (3.28 ft) length (for connecting CT9557 total output to PW6001 or PW3390 only)



SENSOR UNIT CT9557
- Power supply for current sensors when used alone 
- 4ch, with Waveform/Total Waveform/Total RMS output



AC/DC CURRENT PROBE CT6844-05
- DC to 200kHz (Phase: up to 200kHz) 
- Rated 500A AC/DC 
- φ 20 mm (0.79 in) core dia.




AC/DC CURRENT PROBE CT6845-05
- DC to 100kHz (Phase: up to 100kHz) 
- Rated 500A AC/DC 
- φ 50 mm (1.97 in) core dia.



AC/DC CURRENT SENSOR CT6904
- DC to 4 MHz (Phase: up to 1 MHz)
- Rated 500A AC/DC 
- φ 32 mm (1.26 in) core dia.



VOLTAGE CORD L9438-50
- 1000 V specifications, Black/ Red, 3 m (9.84 ft) length, Alligator clip ×2




VOLTAGE CORD L1000
- 1000 V specifications, Red/ Yellow/ Blue/ Gray each 1, Black 4, Alligator clip ×8, 3m (9.84ft) length



WIRING ADAPTER PW9000
- For three-phase 3-wire




WIRING ADAPTER PW9001
- For three-phase 4-wire



PATCH CORD L1021-01
- Banana branch-banana, Red: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V



PATCH CORD L1021-02 
- Banana branch-banana, Black: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V



GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V



EXTENSION CABLE SET L4931
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) lengthExpands the length of the cable with banana plug, 1.5 m (4.92 ft) length
- Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length

OPTIONS


PW3390-03
- D/A output, motor analysis

Ratings & Reviews

No reviews available

Be the first to Write a Review