POWER ANALYZER PW6001-01 (1 CH)

(0) No Reviews yet
$12,000.00
SKU: PW6001-01

Indent Basis Only

Production delay is expected due to the worldwide component shortages. Please contact a Hioki representative for details.


Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW6001 is Hioki's flagship power analyzer, featuring high accuracy, wide band, and high stability for measuring electrical power from DC to inverter frequencies, providing maximum of 12 channels* to support single- and three-phase inverter motor system measurements and next generation devices such as silicon-carbide (SiC) inverters.
*When synchronizing two 6-channel models connected via optical link

Key Features
- Exclusive current sensor phase shift function lets you maintain accuracy even in high frequency, low power factor applications
- Basic accuracy of 0.02%*1 for power measurement *1 PW6001 accuracy only. Instrument delivers accuracy of 0.07% even after the current sensor accuracy has been added.
- High noise resistance and stability (80 dB/100 kHz CMRR, 0.01%/degree C temperature characteristics)
- Accurate measurement even when the load is characterized by large fluctuations; TrueHD 18-bit resolution
- 10 ms data refresh while maintaining maximum accuracy (using a specially designed IC to make all measurements independently while performing simultaneous calculations.)
- DC accuracy of 0.07%, which is key for stable, accurate efficiency measurement
- Wide frequency bandwidth of DC, or 0.1 Hz to 2 MHz
- Achieve true frequency analysis with high-speed 5MS/s sampling (18 bit)
- Synchronize 2 units for up to 12 channels*2 in real time
*2 Two 6-channel models can be connected with an optical connection cable
- Special triggers to enable waveform analysis and motor analysis without the need for an oscilloscope

Measurement line typeSingle-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Number of input channelsMax. 6 channels; each input unit provides 1 channel for simultaneous voltage and current input
(Voltage measurement unit: Photoisolated input, resistance voltage divider, Current measurement unit: Isolated input from current sensor)
Measurement itemsVoltage (U), current (I), active power (P), apparent power (S), reactive power (Q), power factor (λ), phase angle (φ), frequency (f), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)
Harmonic measurement: Harmonic active power, select calculation order
from 2nd order to 100th order
Waveform recording: Voltage and current waveforms/ Motor pulse: Always 5 MS/s
Motor waveforms: Always 50 kS/s, 16 bits
Recording capacity: 1 Mword × ((voltage + current) × number of channels + motor
waveforms)
Motor analysis (PW6001-11 to -16 only): Voltage, Torque, Rotation, Frequency, Slip, or Motor output
Measurement rangeVoltage range: 6 to 1500 V, 8 ranges
Current range (Probe 1) : 400 mA to 1 kA (depends on current sensor)
Current range (Probe 2) : 100 mA to 50 kA (depends on current sensor)
Power range: 2.40000W to 4.50000MW (depends on combination of voltage and current range)
Frequency range: 0.1 Hz to 2 MHz
Basic accuracyVoltage: ±0.02 % rdg. ±0.02 % f.s.
Current: ±0.02 % rdg. ±0.02 % f.s. + current sensor accuracy
Active power: ±0.02 % rdg. ±0.03 % f.s. + current sensor accuracy
Synchronization frequency rangePower measurement: 0.1 Hz to 2 MHz
Harmonic measurement: 45 Hz to 66 Hz (IEC standard mode), 0.1 Hz to 300 kHz (Wideband mode)
Frequency bandDC, 0.1 Hz to 2 MHz
Data update ratePower measurement: 10 ms/ 50 ms/ 200 ms
Harmonic measurement: 200 ms (IEC standard mode), 50 ms (Wideband mode
Data save intervalOFF, 10 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes
User-selected from all measured values, including harmonic measured values,
Specified measured values can be saved in internal memory or USB flash drive
External interfacesUSB (memory), LAN, GP-IB, RS-232C (for communication/LR8410 link), External control ,Synchronization control
Logger connectivitySends measured values wirelessly to logger by using a Bluetooth® wireless technology serial conversion adapter. (Supported devices: Hioki LR8410 Link-compatible loggers), Ver. 2.0 and later
Power supply100 to 240 V AC, 50/60 Hz, 200 VA max
Dimensions and mass430 mm (16.93 in)W × 177 mm (6.97 in)H × 450 mm (17.72 in)D, 14 kg (49.4 oz) (PW6001-16)
AccessoriesInstruction Manual ×1, Power cord ×1, D-sub connector × 1 (PW6001-1x only)

ACCESSORIES




CLAMP ON PROBE 3274
- DC to 10MHz (-3dB) 
- 150Arms maximum input 
- 0.01V/A output 
- φ 20 mm (0.79 in) core dia.



CLAMP ON PROBE 3275
- DC to 2MHz (-3dB) 
- 500Arms maximum input 
- 0.01V/A output 
- φ 20 mm (0.79 in) core dia.



OPTICAL CONNECTION CABLE L6000
- 50/125 μm wavelength multimode fiber, 10 m (32.81 ft) length



GP-IB CONNECTOR CABLE 9151-02
- RS-232C CABLE 9637



CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length



CONNECTION CABLE 9444
- 9 pin - 9 pin straight, 1.5 m (4.92 ft) length



AC/DC CURRENT PROBE CT6843-05
- DC to 500kHz (Phase: up to 300kHz) 
- Rated 200A AC/DC 
- φ 20 mm (0.79 in) core dia.



AC/DC CURRENT SENSOR CT6862-05
- DC to 1MHz (Phase: up to 300kHz) 
- Rated 50A AC/DC 
- φ 24 mm (0.94 in) core dia.



AC/DC CURRENT SENSOR CT6863-05
- DC to 500kHz (Phase: up to 300kHz) 
- Rated 200A AC/DC 
- φ 24 mm (0.94 in) core dia.



AC/DC CURRENT PROBE CT6841-05
- DC to 1MHz (Phase: up to 300kHz) 
- Rated 20A AC/DC 
- φ 20 mm (0.79 in) core dia.



CLAMP ON SENSOR 9272-05
- 1Hz to 100kHz (Phase: 5Hz to 50kHz) 
- Rated 20A/200A AC/DC 
- φ 46 mm (1.81 in) core dia.



GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V




CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length



RS-232C CABLE 9637



CONVERSION CABLE CT9900
- Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal



SENSOR UNIT CT9557
- Power supply for current sensors when used alone 
- 4ch, with Waveform/Total Waveform/Total RMS output



CLAMP ON PROBE 3273-50
- DC to 50MHz (−3dB) 
- 30 Arms maximum 
- φ 5 mm (0.20 in) Core dia.



CLAMP ON PROBE 3276
- DC to 100 MHz (−3dB) 
- 30 Arms maximum 
- φ 5 mm (0.20 in) Core dia.



CONNECTION CABLE CT9904
- ME15W (12 pin) terminal to ME15W (12 pin) terminal, 1 m (3.28 ft) length (for connecting CT9557 total output to PW6001 or PW3390 only)



CURRENT PROBE CT6700
- DC to 50 MHz (-3dB) 
- 5 Arms maximum 
- 1 V/A output 
- φ 5 mm (0.20 in) core dia.



CURRENT PROBE CT6701
- DC to 120 MHz (-3dB) 
- 5 Arms maximum 
- 1 V/A output 
- φ 5 mm (0.20 in) core dia.



VOLTAGE CORD L9438-50
- 1000 V specifications, Black/ Red, 3 m (9.84 ft) length, Alligator clip ×2



VOLTAGE CORD L1000
- 1000 V specifications, Red/ Yellow/ Blue/ Gray each 1, Black 4, Alligator clip ×8, 3m (9.84ft) length




PATCH CORD L1021-01
- Banana branch-banana, Red: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V



PATCH CORD L1021-02
- Banana branch-banana, Black: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V



GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

OPTIONS


PW6001-11
- 1ch, motor analysis, D/A output


PW6001-02
- 2ch


PW6001-12
- 2ch, motor analysis, D/A output


PW6001-03
- 3ch


PW6001-13
- 3ch, motor analysis, D/A output


PW6001-04
- 4ch


PW6001-14
- 4ch, motor analysis, D/A output


PW6001-05
- 5ch


PW6001-15
- 5ch, motor analysis, D/A output


PW6001-06
- 6ch


PW6001-16
- 6ch, motor analysis, D/A output

Ratings & Reviews

No reviews available

Be the first to Write a Review