Power Quality Analyzer PQ3198
Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The new and improved PQ3198 is a power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues. New features include the ability to drive current sensors straight from the PQA and enhanced recording capabilities.
Key Features
- Verify power problems in accordance with the IEC61000-4-30 Class A standard
- High accuracy and continuous gapless recording (V: 0.1% of nominal voltage, A: 0.1% rdg. 0.1% f.s., W: 0.2% rdg. 0.1% f.s.)
- Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
- Maximum 6000 V peak transient voltage up to 700 kHz
- Measure up to 6000 A AC
- Two systems of power measurement and efficiency calculation for (ch 1, ch 2, ch 3)
Included Accessories:
Instruction manual ×1, Measurement guide ×1, Voltage Cord L1000 ×1 set (Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×8), Color clip, AC Adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, SD Memory Card 2GB Z4001 ×1, Application software (PQ ONE) ×1
Measurement line type | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement) |
---|---|
Voltage ranges | Voltage measurement: 600.00 V rms Transient measurement 6.0000 kV peak |
Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use) |
Power ranges | 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use) |
Basic accuracy | Voltage: ±0.1% of nominal voltage Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy |
Measurement items | 1. Transient voltage : 2 MHz sampling 2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz 3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle Current (1/2) RMS: half-cycle calculation 4. Voltage swell, Voltage dips, Voltage interruption 5. Inrush current 6. Voltage waveform comparison 7. Instantaneous flicker value: As per IEC61000-4-15 8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz 9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz 10. Voltage waveform peak, Current waveform peak 11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency 12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz 13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders 14. Harmonic voltage-current phase angle: 1th to 50 th orders 15. Total harmonic distortion factor (voltage/ current) 16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order 17. K Factor (multiplication factor) 18. IEC Flicker, Δ V10 Flicker |
Record | Repeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day) Repeated off: 35 days, maximum recording event: 9999 events |
Interfaces | SD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication) |
Display | 6.5-inch TFT color LCD (640 × 480 dots) |
Power supply | AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack Z1003 (Continuous use: 180 minutes, Charging time: Max. 5 hr 30 m with AC adapter) |
Dimensions and mass | 300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 2.6 kg (91.7 oz) (including Battery Pack Z1003) |
Included Accessories | Instruction manual ×1, Measurement guide ×1, Voltage Cord L1000 ×1 set (Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×8), Color clip, AC Adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, SD Memory Card 2GB Z4001 ×1, Application software (PQ ONE) ×1 |
ACCESSORIES
EXTENSION CABLE L0220-02
- 5 m (16.41 ft) length
EXTENSION CABLE L0220-01
- 2 m (6.56 ft) length
EXTENSION CABLE L0220-03
- 10 m (32.81 ft) length
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
- DC to 5 kHz (-3dB)
- Rated 600 A AC/DC
- φ 33 mm (1.30 in) core dia
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
- DC to 5 kHz (-3dB)
- Rated 100 A AC/DC
- φ 33 mm (1.30 in) core dia.
CARRYING CASE C1002
- For the PW3198, hard trunk type, for storing options
AC CURRENT SENSOR CT7136
- 600 A AC, φ46 mm (1.81 in), 2.5 m (8.20 ft) cord length
AC CURRENT SENSOR CT7131
- 100 A AC, φ15 mm (0.59 in), 2.5 m (8.20 ft) cord length
AC CURRENT SENSOR CT7126
- 60 A AC, φ15 mm (0.59 in), 2.5 m (8.20 ft) cord length
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
EXTENSION CABLE L0220-02
- 5 m (16.41 ft) length
EXTENSION CABLE L0220-01
- 2 m (6.56 ft) length
EXTENSION CABLE L0220-03
- 10 m (32.81 ft) length
MAGNETIC STRAP Z5020
- Extra strength
MAGNETIC STRAP Z5004
LAN CABLE 9642
- Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
AC LEAKAGE CURRENT SENSOR CT7116
- 6 A AC, φ40 mm (1.57 in), 2.5 m (8.20 ft) cord length
MAGNETIC ADAPTER 9804-02
- Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)
GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
CONVERSION CABLE L9910
- Used to connect the current sensors with BNC terminal to PL14 terminal (example the PQ3100)
BATTERY PACK Z1003
- NiMH, Charges while installed in the main unit
AC ADAPTER Z1002
- For main unit, 100 to 240 V AC
GPS BOX PW9005
- To synchronize the PW3198 clock to UTC
SD MEMORY CARD Z4003
- 8 GB capacity
SD MEMORY CARD 2GB Z4001
- 2 GB capacity
PATCH CORD L1021-01
- Banana branch-banana, Red: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V
PATCH CORD L1021-02
- Banana branch-banana, Black: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V
MAGNETIC ADAPTER 9804-01
- Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)
GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
WIRING ADAPTER PW9001
- For three-phase 4-wire
WIRING ADAPTER PW9000
- For three-phase 3-wire
VOLTAGE CORD L1000
- 1000 V specifications, Red/ Yellow/ Blue/ Gray each 1, Black 4, Alligator clip ×8, 3m (9.84ft) length
MAGNETIC ADAPTER 9804-02
- Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)
DOWNLOADS
Catalog
- POWER QUALITY ANALYZER PQ3198, PQ3100
Declaration of Conformity
- POWER QUALITY ANALYZER PQ3198