Resistance HiTester (with Built-in GP-IB) RM3543-01
Built in GP-IB interface
Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3543 is designed to be integrated into current sensing resistor taping machines, deliver high-accuracy measurement of super-low-resistance levels, and are advanced enough to measure 0.1 mohm shunts with room to spare.
Key Features
- Advanced enough to measure 0.1 mohm shunts with room to spare at 0.16% accuracy & 0.01microohm resolution performance
- Superb repeatable measurement accuracy
- Advanced contact-check, comparator, and data export functions
- Intuitive user interface and strong noise immunity are ideal for automated systems
Product Warranty Period: 3 years
Included Accessories:
Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1
Measurement method | Four-terminal, constant-current DC |
---|---|
Resistance range | 10 mΩ (Max. 12.00000 mΩ, 0.01 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 7 steps |
Display | Monochrome graphic LCD 240 × 64 dot, white LED backlight |
Measurement accuracy | [at 10 mΩ range, with SLOW mode, average 16 times settings] ±0.060 % rdg. ±0.001 % f.s. |
Testing current | [at 10 mΩ range] 1 A DC to [at 1000 Ω range] 1 mA DC |
Open-terminal voltage | 20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 MΩ) |
Sampling rate | FAST, MEDIUM, SLOW, 3 settings |
Integration time | [at 10 mΩ range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC, Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) |
Other functions | Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. |
Interfaces | External I/O, RS-232C, Printer, GP-IB (Model RM3543-01) |
External I/O | Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc. |
Power supply | 100 to 240 V AC, 50/60 Hz, 40 VA max. |
Dimensions and mass | 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz) |
Included Accessories | Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1 |
ACCESSORIES
GP-IB CONNECTOR CABLE 9151-02
- 2 m (6.56 ft) length
RS-232C CABLE 9637
- For the PC, 9 pin - 9 pin, cross, 1.8 m (5.91 ft) length
TEST FIXTURE 9262
- Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)
SMD TEST FIXTURE 9263
- Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)
4-TERMINAL PROBE 9140
- DC to 100 kHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω
DOWNLOADS
Catalog
- RESISTANCE HiTESTER RM3543
Declaration of Conformity
- RESISTANCE HiTESTER RM3543,RM3543-01