Clamp on Power Logger w/ Harmonics PW3360-21
HIOKI Clamp On Power Meters are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3360 compact 3-Phase 4-Wire energy loggers monitor power demand and other power parameters to aid in energy audits and validate energy saving measures.
Key Features
- Supports single to three-phase, 4-wire circuits
- Measure between 90V to 780V
- Simultaneously measure up to three single phase, 2 wire circuits (in the same power system)
-Slim, compact design that can be placed anywhere
-Store months of data on SD cards
-The QUICK SET function guides you in making the right connections
-Choose PW3360-21 for harmonic measurements up to the 40th order
Product Warranty Period: 3 years
Included Accessories:
Voltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip ×1 set: red, yellow, blue, white/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5
Measurement line & number of circuits | 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels |
---|---|
Measurement items | Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input [PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order |
Voltage ranges | 600 V AC (Effective measurement range: 90.00 V to 780.00 V) |
Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use), 50.000 mA to 5.0000 A AC (Leak clamp on sensor only) |
Power ranges | 300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type) |
Basic accuracy | Voltage : ±0.3% rdg. ±0.1% f.s Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1) |
Display update rate | 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) |
Save destination | SD memory card, or internal memory at real time |
Data save interval | 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections |
Save items | Measurement value save: Average only / Average, Max./Min. value, [PW3360-21 only]: Harmonic data save: Average only / average, max./min. value in binary format, Screen copy: BMP form (saved every 5 min. at minimum interval time), Waveform save: Binary waveform data |
Interfaces | SD/SDHC memory card LAN 100BASE-TX: HTTP server function USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal |
Functions | Connection check, Quick Set navigation guide, clock, pulse input |
Power supply | AC Adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter) Battery Pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off) |
Dimensions and mass | 180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002 180 mm (7.09 in) W × 100 mm (3.94 in) H × 67.2 mm (2.65 in) D, 830 g (29.3 oz) with PW9002 |
Included Accessories | Voltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip ×1 set: red, yellow, blue, white/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5 |
CLAMP ON SENSOR 9660
- 40Hz to 5kHz, ±0.3% accuracy
- Rated 100 A AC, 1 mV/A output rate
CLAMP ON SENSOR 9661
- 40Hz to 5kHz, ±0.3% accuracy
- Rated 500 A AC, 1 mV/A output rate
CLAMP ON SENSOR 9669
- 40Hz to 5kHz, ±1.0% accuracy
- Rated 1000 A AC, 0.5 mV/A output rate
CLAMP ON SENSOR 9694
- 40Hz to 5kHz, ±0.3% accuracy
- Rated 5 A AC, 10 mV/A output rate
CLAMP ON SENSOR 9695-02
- 40Hz to 5kHz, ±0.3% accuracy
- Rated 50 A AC, 10 mV/A output rate
CLAMP ON SENSOR 9695-03
- 40Hz to 5kHz, ±0.3% accuracy
- Rated 100 A AC, 1 mV/A output rate
CONNECTION CABLE 9219
- Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length
CLAMP ON LEAK SENSOR 9657-10
- 40 Hz to 5 kHz, ±1.0 accuracy
- Rated 10 A AC, 100 mV/A output rate
CLAMP ON LEAK SENSOR 9675
- 40 Hz to 5 kHz, ±1.0% accuracy
- Rated 10 A AC, 100 mV/A output rate
CLAMP ON ADAPTER 9290-10
- Primary 1000A, secondary 100A (1/10 ratio) output
- Superior phase angle characteristics for power
MAGNETIC ADAPTER 9804-01
- Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)
MAGNETIC ADAPTER 9804-02
- Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)
VOLTAGE CORD L9438-53
- Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) length, Alligator clip ×4
AC ADAPTER Z1006
- 100 to 240 V AC
VOLTAGE LINE POWER ADAPTER PW9003
- For PW3360, supplies power from measurement lines, up to 240V AC
BATTERY SET PW9002
- Battery case and Battery Pack 9459 Set
BATTERY PACK 9459
- NiMH, Charges while installed in the main unit
SD MEMORY CARD 2GB Z4001
- 2 GB capacity
SD MEMORY CARD Z4003
- 8 GB capacity
MAGNETIC STRAP Z5004
- Strap with magnet
POWER LOGGER VIEWER SF1001
For PW3360, PW3365 and 3169 series
Trend graph presentation
Summary, daily, weekly, and monthly reports and printing
Catalog
- CLAMP ON POWER LOGGER PW3360
Manual
- CLAMP ON POWER LOGGER PW3360-20,PW3360-21
Declaration of Conformity
- CLAMP ON POWER LOGGER PW3360-10,PW3360-11,PW3360-20,PW3360-21,PW3360-30,PW3360-31