Mini Data Logger For Temperature LR5011
Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or-nstrumentation signals. The LR5011 logs temperature over 1 channel in as fast as 1 second intervals.
Key Features
- Easily mount the light-weight , pocket-sized loggers in tight spaces
- Easy-to-see dual display
- Transfer data to PC even during recording
- Replace batteries while recording (30 second limit)
- 3 times the memory capacity than predecessor (Record 60,000 data per channel)
- Record without missing fluctuations in STAT mode
- Measurement data is preserved even after the battery dies
- Worry-free backup preserves recorded data even if a new measurement is started by mistake
Product Warranty Period: 3 years
Included Accessories:
LR6 (AA) Alkaline battery (built-in internal) × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1
Key Features
- Easily mount the light-weight , pocket-sized loggers in tight spaces
- Easy-to-see dual display
- Transfer data to PC even during recording
- Replace batteries while recording (30 second limit)
- 3 times the memory capacity than predecessor (Record 60,000 data per channel)
- Record without missing fluctuations in STAT mode
- Measurement data is preserved even after the battery dies
- Worry-free backup preserves recorded data even if a new measurement is started by mistake
Product Warranty Period: 3 years
Included Accessories:
LR6 (AA) Alkaline battery (built-in internal) × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1
Measurement items | Temperature 1ch (with optional sensor) |
---|---|
Measurement range | -40.0 °C to 180.0 °C *Depends on measurement range of sensor |
Basic accuracy | ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C) Note: Basic accuracy is typical value, refer to the detailed catalog |
Storage capacity | Instantaneous value mode: 60,000 data, Statistical value mode: 15,000 data |
Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections |
Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approx. 30 sec. of recording operation and clock while battery is replaced |
Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) |
Interfaces | Infrared optical communications with LR5091, LR5092-20 |
Power supply | LR6 (AA) Alkaline battery × 1, Battery life: Approx. 2 years (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 2 months (Instantaneous recording, with 1-second interval at 20 °C) |
Dimensions and mass | 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz) |
Included Accessories | LR6 (AA) Alkaline battery (built-in internal) × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1 |
ACCESSORIES
TEMPERATURE SENSOR LR9601
- 1 m (3.28 ft) length
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9602
- 5 m (16.41 ft)
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9603
- 10 m (32.81 ft)
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9604
- 45 mm (1.77 in)
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9611
- 1 m (3.28 ft) length
(Lug type)
- Temperature range : -30 to 180 ˚C (-22 to 356 ˚F)
- Response time : 45 sec (90% response time)
- Outer diameter: φ7 mm (0.26 in)
- Inner diameter: φ3.2 mm (0.13 in)"
TEMPERATURE SENSOR LR9612
- 5 m (16.41 ft)
(Lug type)
- Temperature range : -30 to 180 ˚C (-22 to 356 ˚F)
- Response time : 45 sec (90% response time)
- Outer diameter: φ7 mm (0.26 in)
- Inner diameter: φ3.2 mm (0.13 in)
TEMPERATURE SENSOR LR9613
- 10 m (32.81 ft)
(Lug type)
- Temperature range : -30 to 180 ˚C (-22 to 356 ˚F)
- Response time : 45 sec (90% response time)
- Outer diameter: φ7 mm (0.26 in)
- Inner diameter: φ3.2 mm (0.13 in)"
TEMPERATURE SENSOR LR9621
- 1 m (3.28 ft) length
(Sheathed type)
- Temperature range : -40 to 120 ˚C (-40 to 248 ˚F)
- Response time : 90 sec (90% response time)
- Sensor head size: φ4 × 180 mm (0.16 in × 7.09 in)"
TEMPERATURE SENSOR LR9631
- 1 m (3.28 ft) length
(Needle type)
- Temperature range : -40 to 120 ˚C (-40 to 248 ˚F)
- Response time : 20 sec (90% response time)
- Sensor head size: φ1.3 × 25 mm (0.05 in × 0.98 in)"
COMMUNICATION ADAPTER LR5091
- Transfer data from logger to PC
- Transfer setting/clock data from PC to logger
- Free bundled software
WALL-MOUNTED HOLDER LR9901
- Not compatible with Model LR5051
MAGNETIC STRAP Z5004
- Strap with magnet
TEMPERATURE SENSOR LR9601
- 1 m (3.28 ft) length
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9602
- 5 m (16.41 ft)
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9603
- 10 m (32.81 ft)
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9604
- 45 mm (1.77 in)
(Molded plastic type)
- Temperature range : -40 to 180 ˚C (-40 to 356 ˚F)
- Response time : 100 sec (90% response time)
- Sensor head size: φ6 × 28 mm (0.24 in × 1.10 in)"
TEMPERATURE SENSOR LR9611
- 1 m (3.28 ft) length
(Lug type)
- Temperature range : -30 to 180 ˚C (-22 to 356 ˚F)
- Response time : 45 sec (90% response time)
- Outer diameter: φ7 mm (0.26 in)
- Inner diameter: φ3.2 mm (0.13 in)"
TEMPERATURE SENSOR LR9612
- 5 m (16.41 ft)
(Lug type)
- Temperature range : -30 to 180 ˚C (-22 to 356 ˚F)
- Response time : 45 sec (90% response time)
- Outer diameter: φ7 mm (0.26 in)
- Inner diameter: φ3.2 mm (0.13 in)
TEMPERATURE SENSOR LR9613
- 10 m (32.81 ft)
(Lug type)
- Temperature range : -30 to 180 ˚C (-22 to 356 ˚F)
- Response time : 45 sec (90% response time)
- Outer diameter: φ7 mm (0.26 in)
- Inner diameter: φ3.2 mm (0.13 in)"
TEMPERATURE SENSOR LR9621
- 1 m (3.28 ft) length
(Sheathed type)
- Temperature range : -40 to 120 ˚C (-40 to 248 ˚F)
- Response time : 90 sec (90% response time)
- Sensor head size: φ4 × 180 mm (0.16 in × 7.09 in)"
TEMPERATURE SENSOR LR9631
- 1 m (3.28 ft) length
(Needle type)
- Temperature range : -40 to 120 ˚C (-40 to 248 ˚F)
- Response time : 20 sec (90% response time)
- Sensor head size: φ1.3 × 25 mm (0.05 in × 0.98 in)"
COMMUNICATION ADAPTER LR5091
- Transfer data from logger to PC
- Transfer setting/clock data from PC to logger
- Free bundled software
WALL-MOUNTED HOLDER LR9901
- Not compatible with Model LR5051
MAGNETIC STRAP Z5004
- Strap with magnet
DOWNLOADS
Catalog
- DATA LOGGER LR5000 Series
Manual
- TEMPERATURE LOGGER LR5011
Declaration of Conformity
- TEMPERATURE LOGGER LR5011
Catalog
- DATA LOGGER LR5000 Series
Manual
- TEMPERATURE LOGGER LR5011
Declaration of Conformity
- TEMPERATURE LOGGER LR5011