Flexible Clamp on Sensor CT9667-02

(0)No Reviews yet
$440.00
SKU: CT9667-02
Ships in approximately 15 days if not in stock.

Out of stock, coming soon!

Hioki current sensors are best-in-class devices for use with power meters, PQAs and Memory HiCorders. The CT9667 series are flexible Rogowski type AC sensors comprising of 3 different models in various loop diameter sizes from 100 to 254 mm. The 100mm and 180mm diameter sensor also feature extra thin cables for easier looping around complicated wiring. All 3 sensors 500A,5000A ranges, making them ideal for measuring large load current. 

 CAT IV 600 V CAT III 1000 V 

 Key Features
- Thinner cables are easy to use in confined spaces and with complicated wiring (-01, -02) 
- Shaped so that it is easy to route through complex wiring 
- Easily supports large current measurements up to 5000 A - Wide 10 Hz to 20 kHz band with excellent frequency characteristics 
- Choose from three conductor diameter sizes 
- Combine with Hioki power meters or Memory HiCorders (with BNC input terminals) 

Product Warranty Period: 1 year


Included Accessories:
LR6 (AA) alkaline batteries ×2, Instruction manual ×1

CT9667-01CT9667-02CT9667-03
Rated input current5000 A AC/ 500 A AC
Max. allowable input10000 A continuous (45 to 66 Hz, requires derating at frequency)
Bandwidth10 Hz to 20 kHz (±3dB)
Amplitude and phase accuracy±2 % rdg. ±0.3 % f.s. (45 to 66 Hz, at center of flexible loop)
Phase: ±1 deg (45 to 66 Hz)
Output voltage500 mV AC/f.s. (0.1 mV AC/A) at 5000 A range
500 mV AC/f.s. (1 mV AC/A) at 500 A range
Max. rated voltage to earth1000 V AC (CAT III), 600 V AC (CAT IV)
Core diameterφ 100 mm (3.94 in)φ 180 mm (7.09 in)φ 254 mm (10.00 in)
Output terminalBNC
Operating temperature-25 °C to +65 °C
(-13 °F to 149 °F)
-25 °C to +65 °C
(-13 °F to 149 °F)
-10 °C to +50 °C
(14 °F to 122 °F)
Power supplyLR6 (AA) alkaline batteries ×2, Continuous use : 7 days (rated power 35 mVA), or AC adapter 9445-02/-03 (rated power 0.2 VA), or External power supply 5 to 15 V DC (rated power 0.2 VA)
Dust and water resistanceFlexible loop only: IP54
* Do not use when wet.
N/A
Dimensions and massFlexible loop cable diameter: φ7.4 mm (0.29 in),
Cable length: Between flexible loop and battery box: 2 m (6.56 ft),
Output cable: 1 m (3.28 ft), Battery box: 35 mm (1.38 in)W × 120.5 mm (4.74 in)H × 34 mm (1.34 in)D, 280 g (9.9 oz)
Flexible loop cable diameter: φ13 mm (0.51 in), Cable length: Between flexible loop and battery box: 2 m (6.56 ft), Output cable: 1 m (3.28 ft)
Battery box: 35 mm (1.38 in)W × 120.5 mm (4.74 in)H × 34 mm (1.34 in)D, 470 g (16.6 oz)
Included AccessoriesLR6 (AA) alkaline batteries ×2, Instruction manual ×1

ACCESSORIES



AC ADAPTER 9445-02
- For USA, 100 to 240 V AC, 9 V/ 1 A



CONVERSION ADAPTER 9704
- Receiving side BNC (female), output banana (male) *Not compatible with older generation Memory Hicorders with banana input terminals

OPTIONS


CT9667-01
- φ100 mm (3.94 in)


CT9667-03
- φ254 mm (10.00 in)

Ratings & Reviews

No reviews available

Be the first to Write a Review