MEMORY HiCORDER MR8880-20 (4 CH FIXED INPUTS)
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple quick-changing phenomena due to complete isolation between channels and from each channel to the ground. The MR8880 is a data acquisition (DAQ) recorder built in with 4 analog channels that can accept direct input of 600V, enabling measurements of 3-phase systems.
Key Features
- CAT III 600V isolation performance; directly measure a 480V power line
- 4 completely isolated channels let you simultaneously record data on a 3-phase power line plus have one extra channel
- Tough against harsh environments; -10degreeC to 50degreeC operating temperature range
- Built to withstand mechanical shocks and vibrations (ships standard with side protectors)
- Make settings easily with PRESETS function
Product Warranty Period: 3 years
Included Accessories:
Instruction manual ×1, Measurement guide ×1, AC adapter Z1002 ×1, Protection sheet ×1, USB cable ×1, Shoulder strap ×1, Application disk (Wave viewer Wv, communication commands table, CAN Editor) ×1
Number of input units | Up to 4 slots |
---|---|
Number of channels | Max. 16 analog channels (Max. 60 channels when using the MR8902) + standard 8 logic channels + 2 pulse channels Note: For analog units, channels are isolated from each other and from the MR8875’s GND. For CAN unit ports or standard logic terminals or standard pulse terminals, all channels have common GND. |
Measurement ranges (20 div full-scale) | 5 mV to 10 V/div , 11 ranges (when using the MR8901), 500 mV to 50 V/div , 7 ranges (when using the MR8905), resolution : 1/1250 of range |
Max. rated voltage | Between terminals: 150 V DC Between terminal to earth: 100 V AC, DC (when using the MR8901) |
Frequency characteristics | DC to 100 kHz (-3 dB, when using the MR8901) |
Time axis | 200 µs to 5 min/div, 21 ranges, sampling period: 1/100 of range, External sampling possible |
Max. sampling rate | [When using MR8901] 500 kS/s (2 μs period, all channels simultaneously) [When using MR8902] 10 ms (all input channels are scanned at high speed during every recording interval) [When using MR8903] 200 kS/s (5 μs period, all channels simultaneously) External sampling: 200 kS/s (5 μs period) |
Measurement functions | High-speed function (high speed recording), Real-time calculation between channels, FFT calculation, or other functions |
Storage memory capacity | Total 32 M-words (memory expansion: N/A, 8 MW each input unit) Note: 1 word = 2 bytes, therefore 32 Mega-words = 64 Mega-bytes. Note: Storage memory can be allocated depending on the number of channels used at each input unit |
Removable storage | SD card slot ×1, USB 2.0 memory |
Display | Touch-panel operation 8.4-inch SVGA-TFT color LCD (800 × 600 dots) |
Communication interfaces | LAN: 100BASE-TX (DHCP, DNS supported, FTP server/ client, WEB server, send E-mail, command control) USB: USB 2.0 compliant, series mini-B receptacle ×1 (setting / measure with communication command, or file transfer SD card to PC), series A receptacle ×2 (USB memory, USB mouse/ key-board) |
Power supply | 1) AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 56 VA 2) Battery pack Z1003: 7.2 V DC, 36 VA, continuous operation time: 1 hour with back light ON (AC adapter has priority when used in combination with battery pack), Charges while installed in the MR8875, recharging time: 3 hours 3) External DC Power: 10 to 28 V DC, 56 VA, (please contact your HIOKI distributor for connection cord) |
Dimensions and mass | 298 mm (11.73 in)W × 224 mm (8.82 in)H × 84 mm (3.31 in)D, 2.4 kg (84.7 oz), (excluding input units and the Battery pack Z1003) Reference data: 3.47 kg/ 122.4 oz (including the MR8901 ×4 units and the Battery pack Z1003) |
Included Accessories | Instruction manual ×1, Measurement guide ×1, AC adapter Z1002 ×1, Protection sheet ×1, USB cable ×1, Shoulder strap ×1, Application disk (Wave viewer Wv, communication commands table, CAN Editor) ×1 |
ACCESSORIES
CLAMP ON PROBE 9018-50
- Excellent phase characteristics
- 40 Hz to 3 kHz
- 10 to 500A AC
- 0.2V AC/range output
- φ 46 mm (1.81 in) core dia.
CLAMP ON PROBE 9132-50
- Use for level measurement
- 40 Hz to 1 kHz
- 20 to 1000A AC
- 0.2 V AC/range output
- φ 55 mm (2.17 in) core dia.
AC/DC CURRENT SENSOR CT7631
- DC to 10kHz (-3dB)
- Rated 100 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7636
- DC to 10kHz (-3dB)
- Rated 600 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
- DC to 5 kHz (-3dB)
- Rated 100 A AC/DC
- φ 33 mm (1.30 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
- DC to 5 kHz (-3dB)
- Rated 600 A AC/DC
- φ 33 mm (1.30 in) core dia
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
DISPLAY UNIT CM7290
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
DISPLAY UNIT CM7291
- Built in Bluetooth® Smart
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
DIFFERENTIAL PROBE P9000
- Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02)
- For use with input of up to 1 kV AC/DC
- Requires separate power supply
AC ADAPTER Z1008
- 100 to 240V AC
CONNECTION CORD L9790
- Flexible φ 4.1 mm (0.16 in) thin dia.
- Cable allowing for up to 600 V input
- 1.8 m (5.91 ft) length
CONTACT PIN 9790-03
- Red/black set attaches to the ends of the Connection Cord L9790
GRABBER CLIP 9790-02
- Red/black set attaches to the ends of the Connection Cord L9790
ALLIGATOR CLIP L9790-01
- Red/black set attaches to the ends of the Connection Cord L9790
CONNECTION CORD L9198
- φ 5.0 mm (0.20 in) dia.
- Cable allows for up to 300 V input
- 1.7 m (5.58 ft) length
- Small alligator clip
CONNECTION CORD L9197
- φ 5.0 mm (0.20 in) dia
- Cable allows for up to 600 V input
- 1.8 m (5.91 ft) length
- Includes detachable large alligator clips
DIFFERENTIAL PROBE 9322
- For up to 2 kV DC or 1 kV AC
- Use with AC Adapter 9418-15
- Frequency band width up to 10MHz
AC ADAPTER 9418-15
- 100 to 240V AC
AC ADAPTER 9445-02
- For USA, 100 to 240 V AC, 9 V/ 1 A
OUTPUT CORD L9094
- 3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length
LOGIC PROBE 9320-01,9320
- 4 channels for contact voltage signals
- 500ns response
- Miniature terminal type
LOGIC PROBE MR9321,MR9321-01
- 4 isolated channels
- ON/OFF detection of AC/DC voltage
- Large terminal type
CONVERSION CABLE 9323
- Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models
GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
CONVERSION ADAPTER 9199
- Receiving side banana, output BNC terminal
AC ADAPTER Z1008
- 100 to 240V AC
PC CARD 1G 9729
- 1 GB capacity
- PC card adapter bundled
PC CARD 9830
- 2 GB capacity
- PC card adapter bundled
PC CARD 512M 9728
- 512 MB capacity
- PC card adapter bundled
GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
CLAMP ON PROBE 9018-50
- Excellent phase characteristics
- 40 Hz to 3 kHz
- 10 to 500A AC
- 0.2V AC/range output
- φ 46 mm (1.81 in) core dia.
CLAMP ON PROBE 9132-50
- Use for level measurement
- 40 Hz to 1 kHz
- 20 to 1000A AC
- 0.2 V AC/range output
- φ 55 mm (2.17 in) core dia.
AC/DC CURRENT SENSOR CT7631
- DC to 10kHz (-3dB)
- Rated 100 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7636
- DC to 10kHz (-3dB)
- Rated 600 A AC/DC
- 1mV/A output
- φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
- DC to 5 kHz (-3dB)
- Rated 100 A AC/DC
- φ 33 mm (1.30 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
- DC to 5 kHz (-3dB)
- Rated 600 A AC/DC
- φ 33 mm (1.30 in) core dia
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
DISPLAY UNIT CM7290
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
DISPLAY UNIT CM7291
- Built in Bluetooth® Smart
- Use with CT7000 series Current sensor
- DCA, ACA, (DC+AC)A, frequency
- Output to oscilloscopes: WAVE, RMS, PEAK, Hz
- Power supply for single sensor
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
AC/DC CURRENT SENSOR CT7642
- DC to 10kHz (-3dB)
- Rated 2000 A AC/DC
- 0.1mV/A output
- φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
- DC to 5 kHz (-3dB)
- Rated 2000 A AC/DC
- φ 55 mm (2.17 in) core dia.
DIFFERENTIAL PROBE P9000
- Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02)
- For use with input of up to 1 kV AC/DC
- Requires separate power supply
AC ADAPTER Z1008
- 100 to 240V AC
CONNECTION CORD L9790
- Flexible φ 4.1 mm (0.16 in) thin dia.
- Cable allowing for up to 600 V input
- 1.8 m (5.91 ft) length
CONTACT PIN 9790-03
- Red/black set attaches to the ends of the Connection Cord L9790
GRABBER CLIP 9790-02
- Red/black set attaches to the ends of the Connection Cord L9790
ALLIGATOR CLIP L9790-01
- Red/black set attaches to the ends of the Connection Cord L9790
CONNECTION CORD L9198
- φ 5.0 mm (0.20 in) dia.
- Cable allows for up to 300 V input
- 1.7 m (5.58 ft) length
- Small alligator clip
CONNECTION CORD L9197
- φ 5.0 mm (0.20 in) dia
- Cable allows for up to 600 V input
- 1.8 m (5.91 ft) length
- Includes detachable large alligator clips
DIFFERENTIAL PROBE 9322
- For up to 2 kV DC or 1 kV AC
- Use with AC Adapter 9418-15
- Frequency band width up to 10MHz
AC ADAPTER 9418-15
- 100 to 240V AC
AC ADAPTER 9445-02
- For USA, 100 to 240 V AC, 9 V/ 1 A
OUTPUT CORD L9094
- 3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length
LOGIC PROBE 9320-01,9320
- 4 channels for contact voltage signals
- 500ns response
- Miniature terminal type
LOGIC PROBE MR9321,MR9321-01
- 4 isolated channels
- ON/OFF detection of AC/DC voltage
- Large terminal type
CONVERSION CABLE 9323
- Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models
GRABBER CLIP 9243
- Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
CONNECTION CORD L9217
- Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
CONVERSION ADAPTER 9199
- Receiving side banana, output BNC terminal
AC ADAPTER Z1008
- 100 to 240V AC
PC CARD 1G 9729
- 1 GB capacity
- PC card adapter bundled
PC CARD 9830
- 2 GB capacity
- PC card adapter bundled
PC CARD 512M 9728
- 512 MB capacity
- PC card adapter bundled
GRABBER CLIP 9243